z
CD disk or Installation and Operation Manual
z
External power adapter
z
Data port connection cable depending on user order
2.4 Equipment Needed
The cables you need depend on the application. Cable terminated in
appropriate connectors provides support for the following data port
interfaces:
z
V.35 interface:
the interface adapter cable ends in a
34-pin connector
z
RS-530 interface:
the interface adapter cable ends in
a 25-pin D-type connector
z
RS-449 interface:
the interface adapter cable ends in
a 37-pin D-type connector
z
X.21 interface:
the interface adapter cable ends in a
15-pin D-type connector
The required cables are available from ATRIE, or can be prepared in
accordance with the port connector wiring information given in Appendix
A,
Interface Specifications.
The available cable and their respective uses
are listed in
Table 2-1
Table 2-1. Data Port Interface Cables
Purpose
Cable Port
Interface
Cable Connector
End-Type
User
Equipment
Length
V35T
V.35 DCE
M34 Female
V.35 DTE
1 meter
V35C
V.35 DTE
M34 Male
V.35 DCE
1 meter
530T
EIA-530 DTE DB-25 Female
EIA-530 DTE 1 meter
530C
EIA-530 DCE DB-25 Male
EIA-530 DCE 1 meter
449T
RS-449 DTE
DB-37 Female
RS-449 DTE
1 meter
449C
RS-449 DCE
DB-37 Male
RS-449 DCE
1 meter
X21T
X.21 DTE
DB-15 Female
X.21 DTE
1 meter
X21C
X.21 DCE
DB-15 Male
X.21 DCE
1 meter
2.5 Interfaces and Connections
Both the WireSpan 600 and WireSpan 610 versions use the same
2-2