Industrial Managed
Ethernet Switch
User Manual
錯誤
!
使用
[
常用
]
索
引標籤將
Heading
1,Product Manual
套用到您想要在此處
顯示的文字。
Page
28
of
191
Figure 2.20
Connection Setting Webpage
Note that the users will be log out automatically if their sessions or connections are in-active for more than five
minutes. The users will have to login to the managed switch again by entering the username and password again
at the login page.
2.3.2
Auth Server Setting
In addition to the local authentication, the switch can be configured to request for authentication through a
centralized RADIUS or TACACS
+
server when the local authentication fails
.
Figure 2.21 shows the setting
parameters for authentication server while Table 2.3 summarizes the authentication server settings. For the
RADIUS and comparison, please refer to Table 2.4 so that you can choose the solution that best suits
your needs
.
Figure 2.21 Authentication Server Setting
Table 2.3 Authentication Server Settings
Label
Description
Factory Default
Authentication Server
Enable / disable authentication through a
remote authentication server
Disabled
Server Type
Choose Authentication Server type:
RADIUS or . See notes below for
a detailed explanation.
RADIUS
Server IP
/
Name
IP address of the authentication server
NULL
Server Port
Communication port of the authentication
server
1812