Industrial Managed
Ethernet Switch
User Manual
錯誤
!
使用
[
常用
]
索
引標籤將
Heading
1,Product Manual
套用到您想要在此處
顯示的文字。
Page
128
of
191
Figure 2.142 ERPS/Ring Drowdown Menu
2.15.1 ERPS Setting
ERPS Setting
webpage is shown in Figure 2.143
Note that the users should disable the
DIP Switch Control
in
Section 2.3.13 first in order to set up ERPS parameters
.
To set up ERPS on the current managed switch, please
follow the following steps:
1. Enable the ERPS by checking on the
ERPS
’s
Enabled
checkbox.
2. If the users would like to keep the log, please also check the
Log
’s
Enabled
checkbox
.
3. Optionally, if the users want the switch to periodically check the status of the neighboring switches on the
ring topology using heartbeat packets then the user can check the
UERPS
’s
Enabled
checkbox
.
Note
that when this feature is enabled, the recovery time of the ring topology may be longer
.
4. Optionally, the users can fine tune the heartbeat interval by changing the default value 50 milli
-
seconds
to the desired value
.
5. Click on the
Update
button
.
6. Skip down to
Add a new RAPS VLAN
section at the bottom of the webpage
.
Enter the desired
RAPS
VLAN
ID in the field and click the
Add
button
.
The VLAN ID can be the value between 1 to 4094
2.50 summarizes the fields in ERPS Setting webpage
.