Installation, Operation & Maintenance Guide

 

Matterhorn 880/882 

4

1-888-MY-AIR11        CAG-06-21-003        AtmosAir.com

01 

PRODUCT OVERVIEW

The AtmosAir Matterhorn 880 series, models Matterhorn 
880 and 882 ionization generators are commercial and 
residential-sized units intended for installation in air 
conditioning systems or in custom-designed air distribution 
systems in small commercial spaces and typical residential 
houses. AtmosAir equipment is effective in reducing odors 
and harmful pollutants through the introduction of positive 
and negative ions into the air stream to be treated. The 
number and size of the ionization tubes used, is dependent 

on the airflow, size of the space, and severity of the pollution 

and odors. The Matterhorn 880/882 is a 220-250 VAC unit 
equipped with one (1) tube. However, it is capable of being 
supplied with two (2) tubes. The Matterhorn 882 is always 

equipped with two (2) specified tubes. The AtmosAir 

Matterhorn 880 series equipment is designed for minimal 
maintenance efforts. The 880 series has two components that 
require inspection and maintenance: 

1. 

AtmosAir Matterhorn 880 series base unit components

2. 

Ionization tubes

Because there are no moving parts, little maintenance is 
required, and the systems have very low failure rates. For 
more information, read the AtmosAir Matterhorn 880 series 
submittal documents.

Control Panel Diagram

AtmosAir 880/882 Series Control Panel Layout:

Tube 

Size 

Tube 

Number

Flowrate 

(CFM)

mm / inch 

 of WG

Pascals 

(Pa)

Steady 

State (mA)

M-

8

8

0

C

1

1000

0.0102mm

0.0004”

0.01

34

D

1

1500

0.10156mm

0.0040”

1.00

35

E

1

2000

0.10156mm

0.0040”

1.00

35

F

1

2500

0.3048mm

0.0120”

2.99

37

M

-8

82

C

2

2000

0.2032mm 

0.0080”

2.00

34

D

2

3000

0.6121mm 

0.0241”

6.00

35

E

2

4000

1.2243mm

0.0482”

12.00

35

F

2

5000

1.7348mm

0.0683”

17.00

37

Pressure Drop calculated at airflow velocity of 1500 f/m (7.62 m/s)

Pressure Drop Chart

A.  Power Transformer - Inside
B.  Fuse Drawer (+1 Spare Fuse)
C.  Power Cord Socket
D.  5-Step Ion Level Adjustment Knob
E.  System Power Light

A

D

C

B

E

Overall Mounting Plate Dimensions:

Height and Width: 222.25mm (8 ¾“) x 215.90mm (8 ½”)

Содержание Matterhorn 880

Страница 1: ...ts pure natural state where no pollution or contaminants exist while reducing energy use and emissions in the process AtmosAir com CAG 06 21 003 IMPORTANT Save this Document for Future Reference Warra...

Страница 2: ...booklet before beginning the installation Follow each installation or repair step exactly as shown and explained in this guide Observe all local state national and international electrical codes Pay...

Страница 3: ...tallation 5 Mechanical Installation Continued 6 Duct Cut Out and Quick Change Plate Procedure 7 Duct Cut Out and Quick Change Plate Procedure Continued 8 Electrical Installation 8 Installation Dimensi...

Страница 4: ...880 series equipment is designed for minimal maintenance efforts The 880 series has two components that require inspection and maintenance 1 AtmosAir Matterhorn 880 series base unit components 2 Ioniz...

Страница 5: ...ing the blue cap DO NOT TWIST THE TUBE OR MOVE THE EMITTER SCREEN DO NOT OVER TIGHTEN THE TUBE Once the tube is secure return the conductor strap to its normal position and ENSURE SOLID FLAT CONTACT I...

Страница 6: ...r Sales for bracket 8 Units should be installed to allow easy access for maintenance Install units so that the 5 step power adjustment knob and status light are easily accessible and visible 9 In the...

Страница 7: ...re 1 Always measure for clearances for the tubes and wires prior to any other steps Then place the Q C P in the appropriate area 2 Holding the Q C P in place use a marker to trace the INNER perimeter...

Страница 8: ...approximately 6 watts per tube An internal 1 amp slow blow fuse protects the unit Follow proper electrical procedures guidelines and codes for providing power to the systems including requirements for...

Страница 9: ...tion Operation Maintenance Guide Matterhorn 880 882 9 1 888 MY AIR11 CAG 06 21 003 AtmosAir com Contact Us 1 888 MY AIR11 1 888 692 4711 Matterhorn 880 882 Installation Operation and Maintenance Guide...

Страница 10: ...E NEUTRAL BLACK BROWN HOT 120V 240VAC SUPPLY PROVEN GOOD GROUND BLACK BROWN HOT 120V 240VAC SUPPLY M882 FIELD DO NOT SCALE DRAWING M 880 M882 FIELD WIRING DIAGRAM SHEET 1 OF 1 UNLESS OTHERWISE SPECIFI...

Страница 11: ...you with an annual service contract Recommended Maintenance Procedures Visually check the performance of the system by checking the red and green lights on the individual units If both lights are on t...

Страница 12: ...ng or other degeneration of the dielectric material that causes the dielectric to fail and arcing to occur Inspect the tube for black dots indicating failed dielectric 7 If physical inspection has not...

Страница 13: ...use a flathead screwdriver to pop the fuse drawer towards you Above Matterhorn 880 Ionization unit Here you will see there is one Ionization Tube installed towards the center of the device This shoul...

Страница 14: ...an and pure quality air that is typically found at higher mountain elevations AtmosAir s unique and proven air purification process significantly reduces mold controls the spread of bacteria and airbo...

Страница 15: ...GATIONS OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULA...

Отзывы: