background image

Installation, Operation & Maintenance Guide

 

Matterhorn 880/882 

15

1-888-MY-AIR11        CAG-06-21-003        AtmosAir.com

y

y

CLEAN AIR GROUP, INC. – PRODUCT WARRANTY 

Clean Air Group, Inc. d/b/a AtmosAir Solutions (“Clean Air Group”) warrants to the original purchaser of this product (“Customer”), 

that should it prove to be defective by reason of improper materials or workmanship, for 

twenty-four (24) months 

from the date 

of installation, or 

twenty-seven (27) months 

from the date of Clean Air Group’s delivery of the product, whichever occurs first, 

Clean Air Group shall repair or replace the product without charge to the Customer. Proof of malfunction and return of the non-

working product must be presented by the Customer if submitting a warranty claim. This warranty is invalid if the factory applied 

serial number has been altered or removed from the product. This warranty does not cover damage due to acts of God, misuse, 

abuse, negligence, or modification of or to any part of the product. This warranty does not cover damage due to improper 

installation, operation or maintenance, connection to improper voltage or electrical supply, or repair by anyone other than an 

authorized Clean Air Group service provider. To obtain warranty service the Customer must: (1) provide proof of purchase in 

the form of a Bill of Sale or receipted invoice, with evidence that the product is within the warranty period; (2) request a Return 

Merchandise Authorization (“RMA”) from Clean Air Group prior to shipping; and (3) ship the product with the RMA to Clean Air 

Group, freight prepaid, in either its original packaging or packaging affording an equal degree of protection. The product should 

be delivered to 

AtmosAir, 2115 East Cedar Street, Suite 6, Tempe, AZ 85281

. All transportation charges and shipping expenses 

are the Customer’s responsibility. Clean Air Group will return the product by the same method it receives the product. A product 

returned for repair after the warranty period, or that shows damage outside of the warranty coverage described herein, shall be 

repaired for a reasonable charge as determined by Clean Air Group. The Customer will be advised of the cost of repair or 

replacement before Clean Air Group proceeds.  

THE OBLIGATIONS OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS, WHETHER 

EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE. ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND 

FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE TERM OF THE EXPRESS WARRANTY GRANTED HEREIN. 

Some states do not allow limitations on how long an implied warranty lasts, so the foregoing limitation or exclusion may not apply 

to you.  

With the exception of damages resulting from Clean Air Group’s failure to comply with any obligation under federal or state 

warranty laws, Clean Air Group SHALL NOT BE LIABLE TO THE CUSTOMER OR ANY OTHER PERSON OR THIRD PARTY 

FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO CONSEQUENTIAL, SPECIAL, INDIRECT, INCIDENTAL AND 

PUNITIVE DAMAGES AND/OR DAMAGES BY REASON OF INJURY TO ANY PERSON DUE TO ANY DEFECT OR 

MALFUNCTION OF THE PRODUCT OR ANY PART OR PARTS THEREOF OR FOR ANY OTHER REASON. This warranty 

gives you specific legal rights and you may have rights which vary from state to state.  If your product is defective please contact 

Clean Air Group or the dealer where you purchased the unit. 

Disclaimer: 

The air purification technology provided by AtmosAir is intended to improve air quality.  It is not intended to  replace 

reasonable precautions to prevent the transmission of airborne contaminants. Customer, its employees, invitees and all persons 

having access to the serviced premises should comply with all applicable public health laws and guidelines issued by federal, 

state and local governments and health authorities such as the Centers for Disease Control and Prevention (CDC). These 

precautions include but are not limited to wearing face masks, social distancing, hand hygiene and appropriate sanitizing and 

disinfecting. Clean Air Group does not assert that its products can protect people from viruses, bacteria or other airborne 

contaminants, expressly excludes liability for loss or damage arising from any such claims, and does not assume any liability for 

the consequences arising out of the application, use or misuse of its products, including any injury or damage to any person or 

damage to any property as a matter of product liability, negligence, contract or otherwise. 

Manufacturer, 

Anthony M. Abate 

Chief Technology Officer 

Clean Air Group, Inc. 

09 

PRODUCT WARRANTY

Содержание Matterhorn 880

Страница 1: ...ts pure natural state where no pollution or contaminants exist while reducing energy use and emissions in the process AtmosAir com CAG 06 21 003 IMPORTANT Save this Document for Future Reference Warra...

Страница 2: ...booklet before beginning the installation Follow each installation or repair step exactly as shown and explained in this guide Observe all local state national and international electrical codes Pay...

Страница 3: ...tallation 5 Mechanical Installation Continued 6 Duct Cut Out and Quick Change Plate Procedure 7 Duct Cut Out and Quick Change Plate Procedure Continued 8 Electrical Installation 8 Installation Dimensi...

Страница 4: ...880 series equipment is designed for minimal maintenance efforts The 880 series has two components that require inspection and maintenance 1 AtmosAir Matterhorn 880 series base unit components 2 Ioniz...

Страница 5: ...ing the blue cap DO NOT TWIST THE TUBE OR MOVE THE EMITTER SCREEN DO NOT OVER TIGHTEN THE TUBE Once the tube is secure return the conductor strap to its normal position and ENSURE SOLID FLAT CONTACT I...

Страница 6: ...r Sales for bracket 8 Units should be installed to allow easy access for maintenance Install units so that the 5 step power adjustment knob and status light are easily accessible and visible 9 In the...

Страница 7: ...re 1 Always measure for clearances for the tubes and wires prior to any other steps Then place the Q C P in the appropriate area 2 Holding the Q C P in place use a marker to trace the INNER perimeter...

Страница 8: ...approximately 6 watts per tube An internal 1 amp slow blow fuse protects the unit Follow proper electrical procedures guidelines and codes for providing power to the systems including requirements for...

Страница 9: ...tion Operation Maintenance Guide Matterhorn 880 882 9 1 888 MY AIR11 CAG 06 21 003 AtmosAir com Contact Us 1 888 MY AIR11 1 888 692 4711 Matterhorn 880 882 Installation Operation and Maintenance Guide...

Страница 10: ...E NEUTRAL BLACK BROWN HOT 120V 240VAC SUPPLY PROVEN GOOD GROUND BLACK BROWN HOT 120V 240VAC SUPPLY M882 FIELD DO NOT SCALE DRAWING M 880 M882 FIELD WIRING DIAGRAM SHEET 1 OF 1 UNLESS OTHERWISE SPECIFI...

Страница 11: ...you with an annual service contract Recommended Maintenance Procedures Visually check the performance of the system by checking the red and green lights on the individual units If both lights are on t...

Страница 12: ...ng or other degeneration of the dielectric material that causes the dielectric to fail and arcing to occur Inspect the tube for black dots indicating failed dielectric 7 If physical inspection has not...

Страница 13: ...use a flathead screwdriver to pop the fuse drawer towards you Above Matterhorn 880 Ionization unit Here you will see there is one Ionization Tube installed towards the center of the device This shoul...

Страница 14: ...an and pure quality air that is typically found at higher mountain elevations AtmosAir s unique and proven air purification process significantly reduces mold controls the spread of bacteria and airbo...

Страница 15: ...GATIONS OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULA...

Отзывы: