Installation, Operation & Maintenance Guide

 

AtmosSmart 

8

1-888-MY-AIR11        CAG-06-21-003        AtmosAir.com

ATMOSSMART

INDOOR 

SENSOR

5'(1.5m)

120 OR 240VAC

JCT. BOX

REQ'D

120 OR 240VAC

JCT. BOX

REQ'D

5'(1.5m)

10'(3m)

120 OR

240VAC

EACH

10'(3m)

10'(3m)

120 OR

240VAC

EACH

10'(3m)

10'(3m)

120 OR

240VAC

EACH

10'(3m)

120 OR

240VAC

EACH

35'(10m)

35'(10m)

35'(10m)

120 OR 240VAC

JCT. BOX

REQ'D

5'(1.5m)

AtmosEXTender

SIGNAL AMPLIFIER

35'(10m)

120 OR 240VAC

JCT. BOX

REQ'D

5'(1.5m)

120 OR 240VAC

JCT. BOX

REQ'D

5'(1.5m)

BPI 2

BPI 1

5VDC

10'(3m)

10'(3m)

ATMOSMULTIPLIER 4

508 BPI UNITS ATMOSSMART 

CAPABLE CONFIGURATION (8 EXAMPLE)

DO NOT SCALE DRAWING

ATMO 

ATMOSMULTIPLIER 4 + 

AtmosEX 

8 BPI EXAMPLE

SHEET 1 OF 1

3/12/21
3/12/21

HG

SB

UNLESS OTHERWISE SPECIFIED:

SCALE: 1:4 WEIGHT: 

REV.
    

A

Created: 3/3/2021

A

SIZE

TITLE:

ATMOSAIR SOLUTIONS

NAME

DATE

PRODUCTION APPR.

ENG APPR.             

CHECKED

DRAWN                     

FINISH

MATERIAL

INTERPRET GEOMETRIC

TOLERANCING PER:

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL   .xxx

ANGULAR: MACH .xxx  BEND 

TWO PLACE DECIMAL     .xxx

THREE PLACE DECIMAL  

APPLICATION

USED ON

NEXT ASSY

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

ATMOSAIR SOLUTIONS.  ANY 

REPRODUCTION IN PART OR AS A WHOLE

WITHOUT THE WRITTEN PERMISSION OF

ATMOSAIR SOLUTIONS IS PROHIBITED.

5

4

3

2

1

Last Saved: 3/12/2021

XXX

XXX

COMMENTS:

  

XXX
XXX

XXX

JS

As many as 8 AtmosAir BPI units (500 Series and/or Matterhorn Series) can be controlled and monitored via the AtmosSmart™ 

system. More than one BPI unit being controlled is considered a custom application. The AtmosSmart™ systems are available 

in single BPI control or double (two-unit) control, as may be ordered. If more than one BPI unit control is required, then the 

AtmosSmart™ must be ordered that way. If more than a two-unit AtmosSmart™ controller is ordered, and additional BPI units are 

desired or specified, then a master control box is required which can accommodate up to 8 BPI units per AHU. 

Each AtmosSmart™ equipped 508 series/ Matterhorn Series has attached to it a dedicated controller/ communication box (the 

module is named ‘AtmosComms2’) that controls the BPI ionization intensity. 

Содержание AtmosSmart

Страница 1: ...to its pure natural state where no pollution or contaminants exist while reducing energy use and emissions in the process AtmosAir com CAG 06 21 003 IMPORTANT Save this Document for Future Reference W...

Страница 2: ...nd The electrical cable enclosed with your AtmosAir unit must be used as it has a special plug which provides a ground circuit for the equipment Always replace fuse with the same rating and type of fu...

Страница 3: ...al Product Description 6 Mode of Operation 7 02 INSTALLATION 8 03 STEP BY STEP INSTALLATION INSTRUCTIONS 11 Installing AtmosAir 500 Series in a Duct 11 04 MONITORING DISPLAY INSTALLATION 12 05 ATMOSSM...

Страница 4: ...Air Flow Sensor Differential Pressure Switch Optional Must be Ordered Control Capacity Up to 8 AtmosAir Ionization Systems Standard Unit 2 BPI Requires AtmosMultiplier 4 with Optional AtmosEXTender A...

Страница 5: ...ing oxygen molecules are ionized which aid in cleaning indoor air General Product Description AtmosSmart is an integrated sensor array designed for installation in the RETURN duct of a typical HVAC ai...

Страница 6: ...determining occupancy O3 Ozone HCHO Formaldehyde and PM Particulate Matter The IAQ readings can be output by attaching an HDMI capable display Display is accessible from a HDMI port located in the Se...

Страница 7: ...lter if present or the AHU itself 02 INSTALLATION The Sensor Array is housed in a doubly insulated hi impact plastic enclosure which is placed in the duct work or AHU If placed in the duct a 3 8 8 cm...

Страница 8: ...CH xxx BEND TWO PLACE DECIMAL xxx THREE PLACE DECIMAL APPLICATION USED ON NEXT ASSY PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ATMOSAIR SOLUTIONS AN...

Страница 9: ...above The sensor head reads multiple indoor air quality IAQ data sets in real time by sensing air properties in the Return Air system This configuration allows the sensor to adjust IAQ based on deman...

Страница 10: ...tallation recommendations Each AtmosSmart enabled 500 series Matterhorn Series unit has an AtmosComms2 controller module integrally installed These controller modules communicate with the sensor array...

Страница 11: ...om of the duct A mounting bracket is optional The display shows real time data and is read only It may be folded up out of the way A HDMI port is also provided in the Sensor Body A large remote monito...

Страница 12: ...e supplied ethernet cable between the jack on the AtmosSmart unit to the AtmosComms2 controller Note This is the only jack on the AtmosComms2 system mounted under the ionizer that could receive this c...

Страница 13: ...There are no user serviceable parts inside the sealed Sensor module Sensors will need to be replaced recalibrated generally after 2 calendar years Certified AtmosAir dealers will coordinate sensor mai...

Страница 14: ...NS OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR...

Отзывы: