background image

Installation, Operation & Maintenance Guide

 

AtmosSmart 

4

1-888-MY-AIR11        CAG-06-21-003        AtmosAir.com

01 

PRODUCT OVERVIEW

APPLICATION 

The AtmosSmart ionization system’s sensor head & controller 
is intended to be mounted in the return duct or air handler 
of a heating, cooling, or ventilating system. The standard unit 

simplifies monitoring and control of up to eight (8) AtmosAir™ 

Active Ionization Systems, using BACnet IP Communication.

AtmosSmart

PRODUCT SUBMITTAL

SPECIFICATIONS

Sensor Suite & Test Ranges

Sensor Application

Air Quality Sensor 1

(50 - 550 ppm)

Integral - TVOC 

(Total Volatile Organic 

Compounds)

Air Quality Sensor 2

(0.01 - 4.0 ppm)

Integral - HCHO 

(Formaldehyde 

Concentration)

Air Quality Sensor 3

(0.5 - 250 µg/m3)

Integral - PM 2.5 

(Particulate Matter 2.5)

Humidity Sensor 4

(5% - 95% RH)

Integral

Temperature 5

(-10°C to 50°C)

Integral

Ozone Sensor 6

(2 -50 ppb)

45 ppb Auto-Shutoff

Carbon Monoxide 7

(0.25 - 2.5 ppm)

Integral

Carbon Dioxide 8

(100 - 2500 ppm)

Integral

Air Flow Sensor

Differential Pressure Switch*

(Optional: Must be Ordered)

Control Capacity

Up to 8 AtmosAir™ Ionization 
Systems* Standard Unit (2) BPI
(Requires AtmosMultiplier (4) 
with Optional AtmosEXTender)

AtmosAir Solutions™

CAG-05-21-002

1-888-MY-AIR11

AtmosAir.com

Product Ratings

Ambient Temperature

-10°C to 50°C

Protection Class

0% - 99% 

Non-Condensing

Humidity

0% - 99% 

Non-Condensing

Ingress Protection

IP4I (DIN EN 60529)

Electrical Safety 

Compliance

EN 60730-1

EMC Compliance

EN 60730-1, EN 61000-6-1, EN 

61000-6-3

Directives

2006/95/EC, 2004/108/EC, 

2011/65/EU

Electrical Statistics

Rated Voltage

90 to 240 VAC (Auto Switching)

Frequency

50/60 Hz

Voltage Range

Control - 5 VDC, Cat5e / Cat6

Power Consumption

12 Watts

Current Draw

2.4 Amps (2,400 mA)

Regulation of BPI Control

Algorithm-Based Modulation

Output Current for Modules 5 VDC

Installation Statistics

Required Space [AA508FC]

(L/H/D)

704mm (~27.75”) x 273mm 

(~10.75”) x 241mm (~9.5”)

Sensor Head Size

(L/W/D)

305mm (~12”) x 127mm (~5”) x 

267mm (~10.5”)

Weight Installation

Sensor 1.5kg (~3.3 lbm)

508FC 10.04kg (~22 lbm)

Internet Connection /

Interface

TCP/IP; Optional MSTP

Bacnet IP / BMS HDMI Monitor

Содержание AtmosSmart

Страница 1: ...to its pure natural state where no pollution or contaminants exist while reducing energy use and emissions in the process AtmosAir com CAG 06 21 003 IMPORTANT Save this Document for Future Reference W...

Страница 2: ...nd The electrical cable enclosed with your AtmosAir unit must be used as it has a special plug which provides a ground circuit for the equipment Always replace fuse with the same rating and type of fu...

Страница 3: ...al Product Description 6 Mode of Operation 7 02 INSTALLATION 8 03 STEP BY STEP INSTALLATION INSTRUCTIONS 11 Installing AtmosAir 500 Series in a Duct 11 04 MONITORING DISPLAY INSTALLATION 12 05 ATMOSSM...

Страница 4: ...Air Flow Sensor Differential Pressure Switch Optional Must be Ordered Control Capacity Up to 8 AtmosAir Ionization Systems Standard Unit 2 BPI Requires AtmosMultiplier 4 with Optional AtmosEXTender A...

Страница 5: ...ing oxygen molecules are ionized which aid in cleaning indoor air General Product Description AtmosSmart is an integrated sensor array designed for installation in the RETURN duct of a typical HVAC ai...

Страница 6: ...determining occupancy O3 Ozone HCHO Formaldehyde and PM Particulate Matter The IAQ readings can be output by attaching an HDMI capable display Display is accessible from a HDMI port located in the Se...

Страница 7: ...lter if present or the AHU itself 02 INSTALLATION The Sensor Array is housed in a doubly insulated hi impact plastic enclosure which is placed in the duct work or AHU If placed in the duct a 3 8 8 cm...

Страница 8: ...CH xxx BEND TWO PLACE DECIMAL xxx THREE PLACE DECIMAL APPLICATION USED ON NEXT ASSY PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ATMOSAIR SOLUTIONS AN...

Страница 9: ...above The sensor head reads multiple indoor air quality IAQ data sets in real time by sensing air properties in the Return Air system This configuration allows the sensor to adjust IAQ based on deman...

Страница 10: ...tallation recommendations Each AtmosSmart enabled 500 series Matterhorn Series unit has an AtmosComms2 controller module integrally installed These controller modules communicate with the sensor array...

Страница 11: ...om of the duct A mounting bracket is optional The display shows real time data and is read only It may be folded up out of the way A HDMI port is also provided in the Sensor Body A large remote monito...

Страница 12: ...e supplied ethernet cable between the jack on the AtmosSmart unit to the AtmosComms2 controller Note This is the only jack on the AtmosComms2 system mounted under the ionizer that could receive this c...

Страница 13: ...There are no user serviceable parts inside the sealed Sensor module Sensors will need to be replaced recalibrated generally after 2 calendar years Certified AtmosAir dealers will coordinate sensor mai...

Страница 14: ...NS OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR...