38
8210C–AVR–09/11
Atmel AVR XMEGA D
4.14.20
ADCBCAL1 – ADCB Calibration register 1
• Bit 7:0 – ADCBCAL0[7:0]: ADCB Calibration Byte 1
This byte contains byte 1 of the ADCB calibration data, and must be loaded into the ADCB
CALH register.
4.14.21
TEMPSENSE0 – Temperature Sensor Calibration register 0
TEMPSENSE0 and TEMPSENSE1 contain the 12-bit ADCA value from a temperature measure-
ment done with the internal temperature sensor. The measurement is done in production test at
85
°
C and can be used for single- or multi-point temperature sensor calibration.
• Bit 7:0 – TEMPSENSE0[7:0]: Temperature Sensor Calibration Byte 0
This byte contains the byte 0 of the temperature measurement.
4.14.22
TEMPSENSE1 – Temperature Sensor Calibration register 1
• Bit 7:0 – TEMPSENSE1[7:0]: Temperature Sensor Calibration Byte 1
This byte contains byte 1 of the temperature measurement.
Bit
7
6
5
4
3
2
1
0
+0x25
ADCBCAL1[7:0]
ADCBCAL1
Read/Write
R
R
R
R
R
R
R
R
Initial Value
x
x
x
x
x
x
x
x
Bit
7
6
5
4
3
2
1
0
+0x2E
TEMPSENSE0[7:0]
TEMPSENSE0
Read/Write
R
R
R
R
R
R
R
R
Initial Value
x
x
x
x
x
x
x
x
Bit
7
6
5
4
3
2
1
0
+0x2F
TEMPSENSE1[7:0]
TEMPSENSE1
Read/Write
R
R
R
R
R
R
R
R
Initial Value
0
0
0
0
x
x
x
x