163
8210C–AVR–09/11
Atmel AVR XMEGA D
Figure 14-2.
Timer/counter extensions and port override logic.
14.4
Dead-time Insertion
The dead-time insertion (DTI) unit generates OFF time where the non-inverted low side (LS) and
inverted high side (HS) of the WG output are both low. This OFF time is called dead time, and
dead-time insertion ensures that the LS and HS never switch simultaneously.
OUT0
OUTOVEN0
CCAEN
DTICCAEN
INVEN0
OUT1
OUTOVEN1
CCBEN
INVEN1
Px0
Px1
Channel
A
DTI
LS
HS
OC0A
OC0B
OCALS
OCAHS
WG 0A
WG 0B
WG 0A
CWCM
OUT2
OUTOVEN2
CCCEN
DTICCBEN
INVEN2
OUT3
OUTOVEN3
CCDEN
INVEN3
Px2
Px3
Channel
B
DTI
LS
HS
OC0C
OC0D
OCBLS
OCBHS
WG 0C
WG 0D
OUT4
OUTOVEN4
CCAEN
DTICCCEN
INVEN4
OUT5
OUTOVEN5
CCBEN
INVEN5
Px4
Px5
Channel
C
DTI
LS
HS
OC1A
OC1B
OCCLS
OCCHS
WG 1A
WG 1B
OUT6
OUTOVEN6
DTICCDEN
INVEN6
OUT7
OUTOVEN7
INVEN7
Px6
Px7
Channel
D
DTI
LS
HS
OCDLS
OCDHS
WG 0B
WG 0D
WG 0C
"0"
"0"