17
ATAN0080 [APPLICATION NOTE]
9341B–AVR–02/15
Figure 6-3.
Screen 3
LIN Bus Analyzer Tool
1.
Launch from the application tools menu
→
LIN bus
analyzer
2.
The display logs LIN message traffic (most recent
messages at the top of the display).
3.
Type field - From the perspective of the GUI acting
as a master -
P = Publish (GUI sent PID and data)
S = Subscribe (GUI sent PID, slave responded with
data)
4.
Stop:
Press to stop message logging; changes to
start after being pressed.
5.
Start
: Press to start message logging; changes to
stop after being pressed.
The default software supports 2 LIN message frames:
●
PID = 06, size = 2 bytes: This frame is published by the
GUI to control the ATAB1634 board, e.g., to turn LEDs
ON or OFF.
●
PID = 03, size = 4 bytes: This frame is subscribed to by
the GUI to obtain the status of the ATAB1634 board,
e.g., to find the current potentiometer reading.
If a response is not received for a message that the GUI
subscribes to, a time-out error is displayed for the frame.