AT-HDVS-200-RX
11
Power
Connector
Relay Connector
Locate the included orange Phoenix terminal block and wire the included power supply to the block, as shown
below. Do not use high-torque devices, when securing the wires to the Phoenix terminal block, as this may damage
the screws and/or block.
1.
Insert the wires into the correct terminal on the included Phoenix block, as shown below.
2. Tighten the screws to secure the wires. Do not use high-torque devices as this may damage the screws and/or
connector block.
Black
White
48V DC
power supply
Installation
The AT-HDVS-200-RX provides a
RELAY
port, allowing the control of screens, curtains, and other devices.
Use a 48 V DC relay with no more than 1 A current draw.
When the AT-HDVS-200-RX is powered-on or rebooted,
C1
and
C2
are set to the Normally Open (NO) state.
C2
COM
C1