![Atlas Copco QAS 500 Volvo S2A APP Скачать руководство пользователя страница 101](http://html1.mh-extra.com/html/atlas-copco/qas-500-volvo-s2a-app/qas-500-volvo-s2a-app_instruction-manual_3001967101.webp)
- 101 -
A
B
C
D E
F G H
I
Terminal strip X11
Legend
Wire size :
aa = 0.5mm²
a = 1 mm²
b = 1.5mm²
c = 2.5mm²
d = 4 mm²
e = 6 mm²
f = 10 mm²
g = 16 mm²
h = 25 mm²
i = 35 mm²
j = 50 mm²
k = 70 mm²
l = 95 mm²
bx = 1.5 mm² NSGAFOeU
Note with X11
Connect wires
..b only if S11
is required
or
connect wire 35
to X11-2 if S11
is not required
(O)
b
d
S11 a
X10
10
1
12
12
S1
M1
8
7
6
5
4
3
2
1
M
-
+
G1
-
+
1
Colour code :
0 = black
1 = brown
2 = red
3 = orange
4 = yellow
5 = green
6 = blue
7 = purple
8 = grey
9 = white
54= green/yellow
X10
B7
Canopy
Cubicle
a6
12b
a3
22b
a6
12
a3
22
X11-8
X11-7
a6
35
a6
35
X11-9
a3
37
a3
36
a3
37b
a3
36b
X11-2
X11-1
a3
60b
a6
12b
a3
60
a6
12
X11-4
X11-3
See also Circ.Diagr Power
X11
a3
5
C5
C5
PE
PE
b3
14
c6
12
aa0
CL
aa9
CH
c2
1
C4
C4
B1
B1
A1
A1
B2
B2
C2
C2
a3
5
l0
l0
c2
1
b3
14
l0
l0
aa9
CH
aa0
CL
c6
12
CANBUS
l0
a2
17
A5
A5
a6
12
+
-
2
4
3
a3
11
b6
12
C1
C1
A1
Control module
(configure in UNIT-type 2)
B7
Fuel level sensor
F10
Fuse
G1
Battery 24V
H0
Panel light
K7
Aux.relay for Y7 (O)
M1
Starter motor
P1-3
A-meters
P4
V-meter
R3
Resistor 120 ohm
S1
Battery switch
S2a
Emergency stop button
(S2b: see Power Circuit)
S4
Voltmeter change-over switch
S11d
Selector switch 50/60Hz
(S11a,b see Power Circuit)
S20
ON/OFF switch
V7
Free-wheeling diode Y7 (O)
X9
Terminal strip (See Power Circuit)
X10
15-Pole connector
X11
Terminal strip (See Power Circuit)
X25
Terminal strip
Y7
Air inlet shutdown valve (O)
(O)
Optional equipment
Содержание QAS 500 Volvo S2A APP
Страница 1: ...QAS 500 Volvo S2A APP Instruction Manual for AC Generators English...
Страница 2: ......
Страница 99: ...99 Circuit diagrams...
Страница 112: ......
Страница 113: ......
Страница 114: ...Printed in Belgium 05 2009 2954 3870 00 www atlascopco com...