2
PAGE
Repair Instructions Nr.183.09/00
PHE 50 S
Detaching the
electric
components and
the Softgrip
1
On both sides, loosen the screws (4) and
remove the cover (3).
2
Loosen the screw (A).
3
Lever off the Softgrip (8) from above since
it is fitted at the top (see arrow in illustra-
tion).
4
Loosen the screws (6) and detach the ca-
ble clamp (5).
5
Lay bare the connection cable (9) with the
switch (7). Branch off the connection cable
from the switch (7). Pull the cable clamp
off the switch (7).
6
Loosen the screw (1) and detach the serv-
ice LED-module (2).
Detaching the
locking elements
1
Remove the spring ring (1) with aid of spe-
cial pliers. If necessary, use a screwdriver
for support.
2
Remove the stop (2) and the damper
ring (3).
3
Remove the retainer (4).
4
Push in the plate (5) against resilience -
the locking elements (6) are relieved.
Unscrew and remove the locking ele-
ments (6).
5
Relieve the plate (5) and remove the pres-
sure spring (7).
6
Rotate the machine by 90° to remove the
disc (8) (the disc (8) will fall out).
7
Remove the bearing sleeve (9) and the
O-ring (A).
1
4
3
2
7
6
8
5
9
A
3
1 2
5
4
3
6
7
A
9
8
4