3.3 Electrical
Connections
Warning
The electrical connection must be carried out by an electrician and corresponds to the local
codes. The indications on the motor data plate must correspond to the power supply voltage
and frequency. The installation must include an isolating switch in the power line near to the
unit and be protected against short-circuits by fuses for each phase refer section Overload
relays and fuses or Cable sizes.
The power supply and earthing lines must be of suitable size. refer section Overload relays
and fuses or Cable sizes.
For DOL starters, connect the power supply cables as shown in the electrical diagrams. For
Y/D starters, connect the power supply cables to terminal board (X1) as shown in the picture.
Check the setting of the overload relay. refer section Overload relays and fuses or Cable
sizes.
Electric Cabinet
Example of an electrical cubicle
Reference
Description
F1
Fuse
F4 Overload
relay
K1
Line contactor with integrated Y-D timer
K2 Star
contactor
K3 Delta
contactor
Содержание LF 10
Страница 1: ...Atlas Copco Industrial aluminium piston compressor LF 2 LF 3 LF 5 LF 7 LF 10 Instruction book ...
Страница 2: ......
Страница 12: ...10 2920 7090 00 Instruction book Power Pack with unloading valve Base mounted ...
Страница 18: ...16 2920 7090 00 Instruction book Air flow and regulating system with DOL starter ...
Страница 19: ...2920 7090 00 17 Instruction book Air flow and regulating system with Y D starter ...
Страница 20: ...18 2920 7090 00 Instruction book Air flow and regulating system of trolley ...
Страница 35: ...2920 7090 00 33 Instruction book 9820 2239 26 09 81461D LF 7 up to LF 10 Tank mounted with silencing hood ...
Страница 39: ...2920 7090 00 37 Instruction book Installation proposal for tank mounted unit 250 475 l receiver ...
Страница 40: ...38 2920 7090 00 Instruction book Installation proposal for base mounted unit with optional silencing hood ...
Страница 72: ......
Страница 73: ......
Страница 74: ......