14
2920 7090 00
Instruction book
For LF 2 up to LF 3:
The compressor block as described above, with flanged-on electric motor (M), check
valve (CV) and safety valve (SV).
For LF 5 up to LF 10:
the Compressor Block as described above, with flanged-on electric motor (M) and
solenoid valve (Y1)
The
tank-mounted unit
comprises:
For LF 2 up to LF 3:
The Power pack mounted on a horizontal or vertical air receiver (AR) with air outlet
valve (AV), pressure gauge (Gp), safety valve (SV), air pressure switch with an on/off button (MDR) and
condensate drain valve (Dm).
For LF 5 up to LF 10:
The power pack mounted on an air receiver (AR) with air outlet valve (AV),
pressure gauge (Gp), safety valve (SV), and condensate drain valve (Dm). An electric cubicle (8) includes
the motor starter. A separate air pressure switch (MDR) is provided.
The
base-mounted unit
is a fully operational unit with air pressure switch and on/off switches
mounted on a frame (no air receiver).
LF
Trolley units
are mobile compressors. They are equipped with either a directly flanged electric motor or a
petrol engine. The compressors have two outlet connections:
A connection for compressed air at working pressure.
A connection for compressed air at reduced pressure via a pressure regulator.
The
Full-Feature compressor
is a tank-mounted compressor provided with a Refrigerant dryer with DD & PD
filter. They remove moisture from compressed air by cooling the air to near freezing point. This causes water to
condense. The condensate is automatically drained. The air is warmed up before leaving the dryer.
2.2 Operation
The compressors are extendible with the following options. For detailed information consult Atlas Copco.
Silencing hood
For 90 / 250 /475 Tank Mounted and Base Mounted
Units
Receiver upgrade
Receiver size upgrade
90 to 250 Standard Receiver
Vertical Receiver
upgrade 90 or 250 to 250
Only for 2 and 3hp
475 Receiver
upgrade 90 or 250 to 475
Pneumatic drain
Not available for Trolley versions
Interstage drain
Not available
Transformer
100VA (for cubicle control voltage 400/3/50)
YD only
Motor anti-condensation heaters and
thermistor protection
Used with LF 2-10 with 400V/50Hz and
460V/60Hz
Содержание LF 10
Страница 1: ...Atlas Copco Industrial aluminium piston compressor LF 2 LF 3 LF 5 LF 7 LF 10 Instruction book ...
Страница 2: ......
Страница 12: ...10 2920 7090 00 Instruction book Power Pack with unloading valve Base mounted ...
Страница 18: ...16 2920 7090 00 Instruction book Air flow and regulating system with DOL starter ...
Страница 19: ...2920 7090 00 17 Instruction book Air flow and regulating system with Y D starter ...
Страница 20: ...18 2920 7090 00 Instruction book Air flow and regulating system of trolley ...
Страница 35: ...2920 7090 00 33 Instruction book 9820 2239 26 09 81461D LF 7 up to LF 10 Tank mounted with silencing hood ...
Страница 39: ...2920 7090 00 37 Instruction book Installation proposal for tank mounted unit 250 475 l receiver ...
Страница 40: ...38 2920 7090 00 Instruction book Installation proposal for base mounted unit with optional silencing hood ...
Страница 72: ......
Страница 73: ......
Страница 74: ......