60
2920 7090 00
Instruction book
Condition
Fault
Remedy
Overload relay cut out
Reset overload relay. If the
relay cuts out again after
starting, see "Overload relay
cuts out"
Air pressure above pre-set
starting pressure
Compressor will start when air
pressure is lower than pre-set
starting pressure of air pressure
switch
Overload relay cuts out
Overload relay incorrectly set
Check and adjust. Reset relay
Solenoid valve out of order
Remove and check. Replace if
necessary
Unloader plunger jammed
Inspect and replace parts
where necessary
Blow-off silencer choked
Replace
Ambient temperature too high
Improve ventilation of room
Motor stops and starts too
frequently
See "Too frequent starting/too
short operating periods"
Overcurrent due to motor or
compressor failure
Consult Atlas Copco
Содержание LF 10
Страница 1: ...Atlas Copco Industrial aluminium piston compressor LF 2 LF 3 LF 5 LF 7 LF 10 Instruction book ...
Страница 2: ......
Страница 12: ...10 2920 7090 00 Instruction book Power Pack with unloading valve Base mounted ...
Страница 18: ...16 2920 7090 00 Instruction book Air flow and regulating system with DOL starter ...
Страница 19: ...2920 7090 00 17 Instruction book Air flow and regulating system with Y D starter ...
Страница 20: ...18 2920 7090 00 Instruction book Air flow and regulating system of trolley ...
Страница 35: ...2920 7090 00 33 Instruction book 9820 2239 26 09 81461D LF 7 up to LF 10 Tank mounted with silencing hood ...
Страница 39: ...2920 7090 00 37 Instruction book Installation proposal for tank mounted unit 250 475 l receiver ...
Страница 40: ...38 2920 7090 00 Instruction book Installation proposal for base mounted unit with optional silencing hood ...
Страница 72: ......
Страница 73: ......
Страница 74: ......