Warning screen, element outlet temperature
flashing
˚C
111
The screen shows that the temperature at the outlet of the compressor element is 111 ˚C.
• It remains possible to scroll through other screens (using keys 3 and 5) to check the actual
status of other parameters.
• Press button (1) to stop the compressor and wait until the compressor has stopped.
• Switch off the voltage, inspect the compressor and remedy.
• The warning message will disappear as soon as the warning condition disappears.
Dew-point temperature
For compressors with integrated dryer:
• If the dew-point temperature exceeds the warning level (not programmable), alarm LED (4)
will light up and the related pictograph will appear flashing.
Main screen with warning dew-point temperature
flashing
bar
6.6
• Press arrow key (3) until the actual dew-point temperature appears.
Warning screen, element outlet temperature
flashing
˚C
9
The screen shows that the dew-point temperature is 9 ˚C.
• It remains possible to scroll through other screens (using keys 3 and 5) to check the actual
status of other parameters.
• Press button (1) to stop the compressor and wait until the compressor has stopped.
• Switch off the voltage, inspect the compressor and remedy.
• The warning message will disappear as soon as the warning condition disappears.
Instruction book
API451763
31
Содержание GA18
Страница 1: ...INSTRUCTION BOOK API451763 GA 18 ...
Страница 2: ......
Страница 16: ...2 2 Air flow Flow diagrams Flow diagram GA Pack Instruction book 14 API451763 ...
Страница 56: ...4 Installation 4 1 Dimension drawings GA 15 up to GA 22 Floor mounted Pack Instruction book 54 API451763 ...
Страница 64: ...Position of oil level sight glass Electric cubicle Instruction book 62 API451763 ...
Страница 93: ......