Reference
Compressor control module
K01
Blocking relay
K02
Auxiliary relay, star contactor
K03
Auxiliary relay, delta contactor
K04
Auxiliary relay, load/unload
K05
Auxiliary relay, dryer
K06
Auxiliary relay, general shutdown
I
Start
0
Stop
Reference
Optional equipment
B1
Electronic water drain
Y10
Timer drain
K25
Phase sequence relay
S10
Main switch
R96
Anti-condensation heaters
2.9
Air dryer
Description
Air dryer
Air circuit
Compressed air enters heat exchanger (10) and is cooled by the outgoing, cold, dried air. Water
vapor in the incoming air starts to condense. The air then flows through heat exchanger/
evaporator (4) where the refrigerant evaporates, causing the air to be cooled further to near the
evaporating temperature of the refrigerant. More water condenses. The cold air then flows
through separator (5) where all the condensate is separated from the air. The condensate is
automatically drained. The cold, dried air flows through heat exchanger (10) where it is warmed
up by the incoming air.