7.4
Belt set exchange and tensioning
Read the warning in the
Preventive maintenance schedule
section.
Belt tensioning procedure
Step
Action
1
Stop the compressor, close the air outlet valve and switch off the voltage.
For Full-Feature versions: also stop the dryer. (See section
2
Remove the front panel of the compressor housing.
3
Remove the side, back and top panels of the compressor housing.
4
Loosen the 4 bolts (2) by one turn.
5
Adjust the belt tension by turning tensioning nut (1).
6
The tension is correct when a force of 50 N (11.25 lbf) applied at the midpoint of the belt
causes a deflection of 6 mm (0.23 in).
7
Retighten bolts (2).
8
Refit the bodywork panels.
Belt replacement procedure
Step
Action
1
Stop the compressor, close the air outlet valve and switch off the voltage.
For Full-Feature versions: also stop the dryer.
2
Remove the front panel of the compressor housing.
3
Remove the side, back and top panels of the compressor housing.
4
Loosen the 4 bolts (2) by one turn.