Connect the power supply cables to the inverter Z1 (L1, L2, L3).
5.
Connect the earth conductor to the inverter Z1 (PE).
Note:
A correct cable gland must be used when the supply cable is connected to the
pump. This will give the necessary protection to the electrical cubicle and its
components from dust.
Pump control modes
Refer to
on page 43.
The control modes that follows can be selected:
▪
Local control: The pump accepts the command signals from the control panel.
It also accepts the start and stop command signals from the clock function, if
programmed and set to on.
▪
Remote control: The pump accepts the command signals from the external
switches (remote control). It also accepts the command signals from the
emergency stop, start and stop command signals from the clock function.
▪
LAN control: The pump is controlled through a local network. contact us.
Note:
Modifications must be approved by us.
Stop the pump and switch off the voltage before external equipment is
connected.
Only potential
‑
free contacts are permitted.
Pump status indication
The controller has a potential
‑
free auxiliary NO contacts (NO = normally open)
(K07, K08 and K09) for the remote indication of:
▪
Manual or automatic operation (K07)
▪
Warning condition (K08)
▪
Shutdown condition (K09)
Maximum contact load: 10 A/250 V a.c.
Stop the pump and set the voltage to off before you connect the external
equipment. Contact us.
6.6.
Connect the dry pumping system to the vacuum/
exhaust system
WARNING:
Pipe the exhaust to a suitable treatment plant to prevent the discharge of
dangerous gases or vapours to the surrounding atmosphere.
Installation
07/2021 - ©Atlas Copco
Page 86