3.6.
Electrical data
Table 7 Electrical data
Characteristics
DWS 750 VSD+
DWS 450 VSD+
Units
Dry pump motor rating
22
11
kW
29.5
14.75
hp
Current rating
(380 - 460 V systems)
50 - 60
50 - 60
A
Recommended branch circuit protec-
tion UL
(380 - 460 V systems)
380 V a.c. 70 A
400 V a.c. 70 A
460 V a.c. 60 A
380 V a.c. 35 A
400 V a.c. 35 A
460 V a.c. 30 A
A
Recommended branch circuit protec-
tion IEC
(380 - 460 V systems)
380 V a.c. 80 A
400 V a.c. 63 A
460 V a.c. 63 A
380 V a.c. 40 A
400 V a.c. 32 A
460 V a.c. 32 A
A
Minimum cable size for 380 - 460 V
systems (or corresponding AWG
size)
16 (4)
6 (8)
mm
2
(AWG)
Mains connector for 380 - 460 V sys-
tems
UT16 & UT16 PE
-
The maximum geometric wire gauge for UT16 and UT16 PE is 25 mm
2
and
maximum AWG size is 4 AWG.
Table 8 General electrical data
Description
Rating
Units
Supply voltage 3-phase
380 - 460 (see rating plate)
V a.c.
Frequency
50/60
Hz
Wiring configuration
3 wire plus Earth (ground)
Voltage tolerance range
± 10%
Installation category
II (IEC 60664-1)
Input supply voltage unbalance
Should not exceed 2% when as-
sessed over any one minute peri-
od
Short circuit current rating (when
installed with class T)
5
kA
Second protective earth (ground)
conductor
Must be fitted with a cross
‑
sec-
tional area at least equal to phase
conductor size
Typical earth leakage†
For 380 - 460 V systems:
For DWS 750 VSD+
< 10
mA
Technical data
07/2021 - ©Atlas Copco
Page 22
1950840208_A
Содержание DWS 450 VSD+
Страница 1: ...Dry Screw Vacuum Pump DWS VSD INSTRUCTION MANUAL 1950840208_A Original instructions ...
Страница 132: ...14 Legal declarations ...
Страница 137: ...atlascopco com ...