without a rotating mechanism
♦
Connect the pressure hose to port
»P«
, making
sure it is torsion-free.
♦
Connect the tank hose to port
»T«
, making sure
it is torsion-free.
with a rotating mechanism
♦
Connect the pressure hose to connection
»P«
of
the rotating mechanism motor, making sure it is
torsion-free.
♦
Connect the tank hose to connection
»T«
of the
rotating mechanism motor, making sure it is
torsion-free.
P
R1
R2
T
♦
Remove the cap nuts and plugs from the
»Rotate«
connections and save them for future use. (R1 =
anticlockwise rotation, R2 = clockwise rotation).
♦
Connect the hoses to the connections of the
»Rotate«
function.
♦
Connect both hoses for the
»Rotate«
function,
making sure they are torsion-free.
all models:
♦
Tighten the connections with the right tightening
torques (see section
Screw connections /
Torques
).
♦
Lift the hydraulic attachment a bit and move it.
Check the positions of the hydraulic hoses.
If the hydraulic hoses are too long, they may get
stuck; if they are too short they may affect the
manoeuvrability of the hydraulic attachment.
♦
Replace any hydraulic hoses which are not of the
right length.
25
© 2014 Construction Tools EOOD | No. 3390 5121 01 | 2014-11-19
Original instructions
INSTALLATION