![background image](http://html1.mh-extra.com/html/atlantis/splash-tech-r60/splash-tech-r60_service-manual_3000615026.webp)
Position the body in the fixture or on table, the diaphragm opening faces up. Install the lifter
(9) into the body (8). Install the new diaphragm (10) and washer (11) into the body (8).
NEVER reuse the diaphragm in the
first stage. A used diaphragm will
not clamp securely as required. A
used diaphragm may come loose
during use, causing a severe
regulator malfunction. This is true
with all diaphragm first stages.
Failure to heed this warning may
result in serious injury or death.