Line
Function
Setting range or display
Setting
increment
Basic setting
6375
S
Relay output QX35
Swimming
pool pump Q19
0: None, 2: Process reversing valve Y22, 3: Hot-gas temperature setpoint K31, 4: Electric immersion heater 1 flow K25,
5: Electric immersion heater 2 flow K26, 6: Diverting valve cooling source Y28, 7: Primary pump Q14, 8: Cascade pump Q25,
9: Heat generation lock Y4, 10: Electric immersion heater DHW K6, 11: Circulating pump Q4, 12: Storage transfer pump Q11,
13: DHW intermediate circuit pump Q33, 14: DHW stirring pump Q35, 15: Collector pump Q5, 16: Collector pump 2 Q16,
17: Solar pump external exchanger K9, 18: Solar actuator buffer K8, 19: Solar actuator pool K18,
20: Electric immersion heater buffer K16, 21: Cons circuit pump VK1 Q15, 22: Cons circuit pump VK2 Q18,
23: Swimming pool pump Q19, 24: Heating circuit pump HC3 Q20, 25: 2nd pump speed HC1 Q21, 26: 2nd pump speed HC2 Q22,
27: 2nd pump speed HC3 Q23, 28: Diverting valve heat-/cool circuit 1 Y21, 29: Air dehumidifier K29, 30: Heat demand K27,
31: Cool demand K28, 32: Alarm output K10, 33: Time switch program 5 K13, 34: Heat circuit pump HC1 Q2,
35: DHW actuator Q3, 36: Source pump Q8/fan K19, 37: Condenser pump Q9, 38: Compressor 1 K1, 39: Suppl source control K32,
41: Heat circuit pump HC2 Q6, 42: Instant heater ctrl elem Q34, 43: inadmissable setting , 44: Common flow valve Y13,
45: Diverting valve heat-/cool circuit 2 Y45, 46: Diverting valve heat-/cool circuit 3 Y46, 47: Cooling circ pump CC1 Q24,
48: Cooling circ pump CC2 Q28, 49: Cooling circ pump CC3 Q29, 50: Solid fuel boiler pump Q10,
51: Flue gas relay K17, 52: Assisted firing fan K30, 53: Crankcase heater K40, 54: Drip tray heater K41,
55: Valve evaporator K81, 56: Valve EVI K82, 57: Valve injection capillary K83, 59: Delta-T-controller 1 K21,
60: Delta-T-controller 2 K22, 61: Ventilation fan 1 K51, 62: Ventilation fan 2 K52, 63: Ventilation fan 3 K53,
64: Ventilation bypass 1 K54, 65: Ventilation bypass 2 K55, 66: Ventilation bypass 3 K56, 67: Outside air temperature control Q17,
68: Source intermediate circuit pump Q81, 69: Source intermediate diverting valve Y81, 70: DHW heat pump K33,
71: System pump 2 Q44, 72: Diverting valve cooling condenser Y27, 73: Diverting valve cooling flow Y29,
74: Condenser reversing valve Y91, 75: Buffer reversing valve Y47, 76: Status information heating K42,
77: Status information cooling K43, 78: Status information DHW charging K44, 79: Heating/Cooling circuit pump 1 Q2,
80: Heating/Cooling circuit pump 2 Q6, 81: Heating/Cooling circuit pump 3 Q20
6400
S
Function input H31
None
0: None, 1: Operating mode changeover zones+DHW, 2: Optg mode changeover DHW, 3: Operating mode changeover zones,
4: Operating mode changeover zone 1, 5: Operating mode changeover zone 2, 6: Operating mode changeover zone 3,
8: Error/alarm message, 9: Consumer request VK1, 10: Consumer request VK2, 11: Release swi pool source heat,
13: Release swi pool solar, 14: Operating level DHW, 15: Operating level HC1, 16: Operating level HC2, 17: Operating level HC3,
18: Room thermostat HC1, 19: Room thermostat HC2, 20: Room thermostat HC3, 21: DHW flow switch,
24: Pulse count, 26: Dewpoint monitor, 27: Flow temp setp incr hygro, 30: Switch-on command HP stage 1,
35: Status info suppl source, 36: Charg prio DHW sol fuel boil, 43: Ventilation switch 1, 44: Ventilation switch 2,
45: Ventilation switch 3, 50: Flow measurement Hz, 51: Consumer request VK1 10V, 52: Consumer request VK2 10V,
54: Pressure measurement 10V, 55: Humidity measurement 10V, 56: Room temp 10V, 59: Flow measurement 10V,
60: Temp measurement 10V
6403
S
Input value 1 H31
0
6404
S
Funct value 1 H31
0
6405
S
Input value 2 H31
10
6406
S
Funct value 2 H31
100
6410
S
Function input H32
None
0: None, 1: Operating mode changeover zones+DHW, 2: Optg mode changeover DHW, 3: Operating mode changeover zones,
4: Operating mode changeover zone 1, 5: Operating mode changeover zone 2, 6: Operating mode changeover zone 3,
8: Error/alarm message, 9: Consumer request VK1, 10: Consumer request VK2, 11: Release swi pool source heat,
13: Release swi pool solar, 14: Operating level DHW, 15: Operating level HC1, 16: Operating level HC2, 17: Operating level HC3,
18: Room thermostat HC1, 19: Room thermostat HC2, 20: Room thermostat HC3, 21: DHW flow switch,
24: Pulse count, 26: Dewpoint monitor, 27: Flow temp setp incr hygro, 30: Switch-on command HP stage 1,
35: Status info suppl source, 36: Charg prio DHW sol fuel boil, 43: Ventilation switch 1, 44: Ventilation switch 2,
45: Ventilation switch 3, 50: Flow measurement Hz, 51: Consumer request VK1 10V, 52: Consumer request VK2 10V,
54: Pressure measurement 10V, 55: Humidity measurement 10V, 56: Room temp 10V, 59: Flow measurement 10V,
60: Temp measurement 10V
6413
S
Input value 1 H32
0
6414
S
Funct value 1 H32
0
6415
S
Input value 2 H32
10
6416
S
Funct value 2 H32
100
6420
S
Function input H33 (=H4)
1... 26
Optg mode
change
HCs+DHW
0: None, 1: Optg mode change HCs+DHW, 2: Optg mode changeover DHW, 3: Optg mode changeover HCs,
4: Optg mode changeover HC1, 5: Optg mode changeover HC2, 8: Error/alarm message, 11: Release swi pool source heat,
13: Release swi pool solar, 26: Dewpoint monitor
6421
S
Contact type H33
Normally-closed contact (NC)
Normally-opened contact (NO)
NO
Installation and commissioning instructions "1485 - EN"
Heat pump alféa hybrid duo gas
- 64 -
Содержание WOYG112LHT
Страница 51: ... Installation and commissioning instructions 1485 EN 51 Heat pump alféa hybrid duo gas ...
Страница 69: ... Installation and commissioning instructions 1485 EN 69 Heat pump alféa hybrid duo gas ...
Страница 90: ...Installation and commissioning instructions 1485 EN Heat pump alféa hybrid duo gas 90 ...
Страница 91: ...Installation and commissioning instructions 1485 EN 91 Heat pump alféa hybrid duo gas ...