Prior to Operation and Installation
When the pump is delivered, perform the following checks:
• Check for any damage to pump and power cable that may have occurred during the shipment.
• Check the model number to make sure it is the product that was ordered and verify the
voltage and frequency are correct.
Caution
• DO NOT operate this product under any condition other than those for which it is specified.
Failure to observe this precaution can lead to electrical shock or leakage, fire, water leakage
or other problems.
• A-05/A-05L/A-21/A-31 pumps require a single phase 115 volt / 60 hz power supply. A-32
pump requires a single phase 230 volt / 60 hz power supply. Always verify that the supplied
power meets the requirements listed on the upper pump cover.
• DO NOT apply any paint over the stainless steel motor body. Reduced cooling ability will
result in overheating, overloading, undesirable performance reductions, periodic auto
shut-off and pump malfunction.
• Never place your hand or any object in or near the inlet opening while this equipment is
operating. If pump inlet is clogged, always turn off the power supply, fuse box or circuit
breaker and wait until the motor is completely stopped before attempting to remove any
clogged material.
• Please make sure that the power plug and the AC outlet receptacle is protected and away
from water or pump discharge hose to prevent accidental electric shock or short circuit.
• Always operate the pump completely submerged in water.
• Avoid dry operation, which will not only lower performance but can cause the pump to
overheat/malfunction, leading to electrical leakage, shock or premature failure.
•
CAUTION:
THIS PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND CIRCUIT INTERRUPTER.
Introduction
Thank you for choosing this Atlantic A-Series pump. Before using this pump please take a
moment to review this manual.
To avoid an accident do not use the pump in any way other than as described in this
manual. Please note the manufacturer cannot be responsible for accidents arising because
the product was not used as prescribed. After reading this manual keep it as a reference in
case questions arise during use. Using the pump in a manner that is not prescribed will void
the warranty.
Flow Chart (GPH)
2
* Operating pumps outside of the recommended range may cause bearing damage and
premature failure.
MODEL
MAX FLOW
A-05
---
A-05L
---
A-21
---
A-31
---
AN-32
---
10'
20'
30'
40'
15'
25'
35'
45'
5'
55'
50'
60'
4320
5325
8150
13320
11100
5040
5810
9300
14100
2840
3165
3600
4824
6830
12300
2500
2820
4335
5535
2155
9180
1920
3770
4120
10200
1875
840
3140
2535
1455
7920
2400
625
935
6600
1530
320
5220
540
3900
2520
Best Efficiency Range
Recommended Operating Range
Do Not Operate Range
1320