Atlantic Ultraviolet Mighty Pure MP16A Скачать руководство пользователя страница 6

6

I

NSTALLATION

SAFETY EQUIPMENT REQUIRED TO PERFORM TASK

1.  Remove water puri

fi

 er from shipping carton. Inspect water puri

fi

 er, power cord and plug for damage. Do not operate if 

there is any damage to the puri

fi

 er, power cord or plug.  Models MP16A through MP22A are shipped with the lamp already 

installed, while the lamp in the MP36C and MP49C is packed separately. Keep the lamp aside for installation once the 
puri

fi

 er has been properly installed.

2.  Units occasionally experience damage in shipment due to the fragility of the quartz sleeve.  It is, therefore, recommended to 

inspect the water puri

fi

 er for damage to the quartz sleeve after it has been removed from the shipping carton. Each end of the 

unit as well as the inlet and outlet should be viewed to see if the quartz sleeve has experienced damage. If the quartz sleeve 
shows signs of damage it should be replaced before the puri

fi

 er is pressurized.  See “

Quartz Sleeve Installation, Cleaning 

or Replacement”

 in the 

“Maintenance”

 section for the proper method of replacing the quartz sleeve in your water puri

fi

 er.

3.  The water puri

fi

 er should be mounted horizontally on a 

fl

 at dry surface. Secure the water puri

fi

 er using the mounting  holes 

in the ballast housing or with the optional wall mounting kit. The puri

fi

 er should not be solely supported by its plumbing 

connections.

4.  The water puri

fi

 er must be connected to the cold water line only.

5.  Installation requires that a 5-micron sediment 

fi

 lter or 

fi

 ner be installed, in line, prior to the water puri

fi

 er. The sediment 

fi

 lter 

will stop or trap large particulates from entering the water puri

fi

 er. Particulates may cause damage to the quartz sleeve, as 

well as interfere with the puri

fi

 er’s ability to disinfect the water. The sediment 

fi

 lter may also help to reduce the amount of  

routine cleanings of the quartz sleeve.

6.  Shut off valves should be installed on both the inlet and outlet sides of the water puri

fi

 er. 

The use of bypass valves is not 

recommended

. The shut off valves allow the puri

fi

 er to be isolated from the water supply, which is required when removing 

the quartz sleeve.

7.  Unions should be installed on both the inlet and outlet of the water puri

fi

 er; this will allow easy removal of the water puri

fi

 er 

from the plumbing, if required. Apply Te

fl

 on

®

 tape to threads of inlet and outlet ports to ensure a tight seal.

8.  When all plumbing connections are complete, allow water to enter the water puri

fi

 er at a low 

fl

 ow rate, until the puri

fi

 er is 

full. 

NOTE: Close the puri

fi

 er outlet valve to pressurize the chamber.

 With the puri

fi

 er pressurized, it should be checked 

for leaks. Once it is determined that there are no leaks, the inlet valve can be fully opened. 

9.  For Models with lamps packed separately, install lamp following the steps in “Lamp Installation or Replacement” section.

       CAUTION: Lamp and quartz sleeve are easily damaged. Exercise care when handling. (Continued on Page 7)

Figure 2 - Recommended Installation

Содержание Mighty Pure MP16A

Страница 1: ...PDLO LQIR XOWUDYLROHW FRP Extensive Product Information Available at ultraviolet com Document No 98 1376C October 2015 2015 Atlantic Ultraviolet Corporation Installation Operation Maintenance Read an...

Страница 2: ...INTENANCE NOTES 22 23 USER ASSISTANCE 24 WARRANTY 24 PATENT NOTICE 24 These instructions generally describe the installation operation and maintenance of the Mighty Pure line of water purifiers Models...

Страница 3: ...operate without proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warning...

Страница 4: ...r and flows into the annular space between the quartz sleeve and the chamber wall Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp The translucent sight port...

Страница 5: ...should be located in an area where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purif...

Страница 6: ...cted to the cold water line only 5 Installation requires that a 5 micron sediment filter or finer be installed in line prior to the water purifier The sediment filter will stop or trap large particula...

Страница 7: ...nstalled temporarily for shipping purposes Please follow these instructions if applicable 1 Pull off Easy Off end caps from static gland nut on each end of the water purifier chamber 2 Unscrew static...

Страница 8: ...8 Figure 3 Initial Installation of Quartz Sleeve...

Страница 9: ...lerts the user to any malfunction detected 6 Solenoid Valve Operated in conjunction with the Ultraviolet Monitor Safety Sensor or Time Delay Mechanism this valve prevents water flow through the water...

Страница 10: ...still in operation On purifiers not equipped with the Ultraviolet Monitor lamp operation can be verified by a visible glow through the translucent sight port This provides an indication of lamp operat...

Страница 11: ...to chamber until approximately 2 inches of the lamp is exposed on the opposite end Hold lamp and remove lamp socket 6 Lamp should now be disconnected on both ends Carefully remove lamp from chamber Be...

Страница 12: ...move Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that...

Страница 13: ...of quartz sleeve hold the purifier vertically and shake The quartz fragments will break and drop out of the purifier through the gland fitting Flush water through chamber being careful to remove all...

Страница 14: ...gent and rinse with clean water Stubborn stains usually can be removed with a dilute hydrochloric acid NOTE Follow all manufacturer s instructions and precautions when handling chemicals Once the quar...

Страница 15: ...or fittings Tighten suspect connection or fitting or shut down purifier drain and remove fitting or connection Clean threads reapply thread sealing tape and reinstall Poor purifier performance AND OR...

Страница 16: ...perature 35 F 100 F 35 F 100 F 35 F 100 F 35 F 100 F Quartz Sleeve 1 1 1 1 Drain Plug 1 4 NPT 1 4 NPT 1 4 NPT 1 4 NPT Lamp Out Indicator Translucent Sight Port Translucent Sight Port Translucent Sight...

Страница 17: ...elay Mechanism MP16A through MP49C Quantum Thermal Optimizer MP16A through MP49C Solenoid Valve MP16A 1 2 through MP22A 3 4 MP36C 1 MP49C 1 1 2 MP49C 1 1 2 Sure Flo Flow Control Valve MP16A 3 4 MP22A...

Страница 18: ...18 REPLACEMENT PARTS Mighty Pure MODELS MP16A MP22A Figure 8 Exploded View MP16A MP22A...

Страница 19: ...Quartz Sleeve 1 15 1111A 1 15 1112A 10 Sight Port Plug 1 30 1075 1 30 1075 11 Drain Plug 1 27 1216 1 27 1216 12 Speed Nut 6 32 2 50 1314 2 50 1314 13A Ballast 120v 60Hz 1 10 0137 1 10 0137 13B Ballas...

Страница 20: ...20 Mighty Pure MODELS MP36C MP49C Figure 9 Exploded View MP36C MP49C...

Страница 21: ...465G4 1 25 1465F5 12 Drain Plug 1 27 1216 1 27 1216 13 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034 14 Lock Washer 1 4 4 50 1321 4 50 1321 15 Flat Washer 1 4 4 50 1317 4 50 1317 16 Ballast Housing Cove...

Страница 22: ...22 MAINTENANCE NOTES...

Страница 23: ...23 MAINTENANCE NOTES...

Страница 24: ...een made to determine the patent status of applications illustrated or described in this publication Inclusion in this publication of any design or method of use which may be patented is not to be con...

Отзывы: