INSTALLATION
L
OCATION
1. The water puri
fi
er is intended for indoor use only. The water puri
fi
er is designed to mount horizontally. The water puri
fi
er
should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area
surrounding the water puri
fi
er, should be between 35
o
F and 100
o
F.
2. Electrical power supplied to the water puri
fi
er
MUST
match power requirements listed on the water puri
fi
er. Use of a voltage
surge protector is recommended.
3.
CAUTION:
Plug water puri
fi
er only into an approved ground fault circuit interrupt (GFCI) receptacle.
4. The water puri
fi
er should be located in a dry, well-lit area, which provides enough room to perform routine maintenance. This
includes a minimum distance of one chamber length from the chamber end, to allow for cleaning and/or the changing of the
lamp and quartz sleeve as well as a minimum of 6” on the opposite end of the water puri
fi
er. Minimum clearance to
fl
oor 18’’.
5. The water puri
fi
er should always be located closest to the point of use. This reduces the chance of the puri
fi
ed water being
re-contaminated by bacteria in the water distribution system after the water puri
fi
er.
6.
CAUTION:
As with any water handling device, the water puri
fi
er should be located in an area where any possible
condensation or leakage from the water puri
fi
er, any puri
fi
er accessory and/or plumbing will not result in damage to the
area surrounding the water puri
fi
er. For added protection, it is recommended that a suitable drain pan be installed under the
puri
fi
er. The drain pan must be plumbed to an adequate, free
fl
owing drain to prevent water damage in event of a leak. There
are numerous leak detection/
fl
ood stop devices, available on the market today, designed to stop
fl
ow of water, reducing the
chance of water damage due to leakage. For more details regarding leak prevention and/or limiting damages due to leaks
please contact factory.
7. The water puri
fi
er should be located after all other water devices, such as De-ionizers, Water Softeners, Carbon Filters, Pre-
Filters, Reverse Osmosis, Pressure Tanks, and Pumps. This reduces the chance of the puri
fi
ed water being re-contaminated by
bacteria in any of these units.
D
IMENSIONAL
D
ATA
Figure 1 -Mighty
Pure
®
Dimensional Drawing
Table 2 - Mighty
Pure
®
Dimensional Data
Model
A
B
C
D
E
F
G
H
Inlet/Outlet
MP16A
8-3/4”
16”
8-3/4”
10”
16-1/2”
3-5/8”
4-5/16”
8-3/16”
3/4”m NPT
MP22A
14-3/4”
22”
13-1/4”
14-1/2”
22-1/2”
3-5/8”
4-5/16”
8-3/16”
3/4”m NPT
MP36C
28-1/2”
36”
16”
18”
36-1/2”
4-15/16”
5-11/16”
9-1/2”
1”m NPT
MP49C
40-7/8”
49”
26”
30”
49-1/2”
4-15/16”
5-11/16”
9-1/2”
1- 1/2”m NPT
All speci
fi
cations, dimensional data, etc are approximate and subject to change without notice.
Содержание Mighty Pure MP16A
Страница 8: ...8 Figure 3 Initial Installation of Quartz Sleeve...
Страница 18: ...18 REPLACEMENT PARTS Mighty Pure MODELS MP16A MP22A Figure 8 Exploded View MP16A MP22A...
Страница 20: ...20 Mighty Pure MODELS MP36C MP49C Figure 9 Exploded View MP36C MP49C...
Страница 22: ...22 MAINTENANCE NOTES...
Страница 23: ...23 MAINTENANCE NOTES...