15
TROUBLESHOOTING
WARNING: Always disconnect power to the water puri
fi
er before performing any service or maintenance.
IMPORTANT: This unit is to be serviced ONLY by quali
fi
ed, and appropriately licensed, personnel.
Table 3 - Troubleshooting
Problem
Possible Cause
Corrective Action
Puri
fi
er not operating
No electrical power....
Verify that the puri
fi
er is connected to a live power
source.
Water leaking into/from puri
fi
er.
Cracked or broken quartz sleeve...
Shut down puri
fi
er, drain, and replace quartz
sleeve. See
“Quartz Sleeve Installation, Cleaning
or Replacement”
in the
“Maintenance”
section
Quartz sleeve sealing o-ring (s) worn,
damaged...
Shut down puri
fi
er, drain, and remove static gland
nut, replace sealing o-ring. See
“Quartz Sleeve
Installation, Cleaning or Replacement”
in the
“Maintenance”
section
Poor, or loose, connections or fi ttings
Tighten suspect connection or fi tting; or shut down
purifi er, drain, and remove fi tting or connection.
Clean threads; reapply thread sealing tape and
reinstall.
Poor puri
fi
er performance AND/OR Low UV intensity (As
indicated on optional Guardian
TM
Ultraviolet Monitor)
Quartz sleeve fouled...
Clean quartz sleeve, see “
Quartz Sleeve
Installation,Cleaning or Replacement
” in the
“
Maintenance
” Section.
Sensor Probe, if equipped, lens or
quartz rod fouled...
Clean lens or Quartz Rod, see “
Optional
Ultraviolet Monitor Sensor Probe Cleaning
” in
the “
Maintenance
” section
Germicidal lamp output depreciating...
Replace lamp, as it nears its end of life
(EOL)
.
See “
Lamp Installation or Replacement
” in the
“
Maintenance
” section.
Germicidal lamp not functioning...
Replace lamp. See “
Lamp Installation or
Replacement
” in the “
Maintenance
” section
Low input voltage...
Verify input voltage to puri
fi
er.
Change in water quality....
Have water tested to con
fi
rm that it does not
exceed maximum recommended concentration
levels for use with this puri
fi
er.
Содержание Mighty Pure MP16A
Страница 8: ...8 Figure 3 Initial Installation of Quartz Sleeve...
Страница 18: ...18 REPLACEMENT PARTS Mighty Pure MODELS MP16A MP22A Figure 8 Exploded View MP16A MP22A...
Страница 20: ...20 Mighty Pure MODELS MP36C MP49C Figure 9 Exploded View MP36C MP49C...
Страница 22: ...22 MAINTENANCE NOTES...
Страница 23: ...23 MAINTENANCE NOTES...