Atlantic Ultraviolet Mighty Pure MP16A Скачать руководство пользователя страница 21

21

Table 7 - Replacement Parts MP36C &MP49C

Item No.

Description

MP36C

MP49C

Quantity

Part Number

Quantity

Part Number

1

Easy-Off 

TM

 End Cap

2

25-1499A1

2

25-1499A1

2

O-Ring, Static Gland

2

00-1108B

2

00-1108B

3

Lamp Spacer

-

-

2

25-0209A

4

Lead Wire & Socket

2

05-1218A2

2

05-1218A2

5

Lamp

1

05-1343-R

1

05-1334-R

6

Static Gland Nut

2

25-1492D

2

25-1492D

7

Te

fl

 on

®

 Washer

2

25-1235A

2

25-1235A

8

O-Ring, Quartz Sleeve

2

00-1238A

2

00-1238A

9

Quartz Sleeve

1

15-1113A

1

15-1114A

10

Sight Port Plug

1

30-1075

1

30-1075

11

Chamber

1

25-1465G4

1

25-1465F5

12

Drain Plug

1

27-1216

1

27-1216

13

Screw, 1/4”-20 x 3/8” long

4

50-1034

4

50-1034

14

Lock Washer, 1/4”

4

50-1321

4

50-1321

15

Flat Washer 1/4”

4

50-1317

4

50-1317

16

Ballast Housing Cover

1

25-0394A

1

25-0350A

17

Screw, No. 8 x 3/8” long

8

50-1323

8

50-1323

18

Speed Nut, 6-32

2

50-1314

2

50-1314

19A

Ballast, 120v 60Hz

1

10-0137

1

10-0091

19B

Ballast, 220v 50Hz

1

10-0136

1

10-0127

20

Ballast Housing

1

25-0395D

1

25-0351B

21

Screw, Mounting

2

50-0376

2

50-0376

22A*

Line Cord (120v 60Hz)

1

35-1100

1

35-1100

22B*

Power Cord 6’ (220v 50Hz)

1

35-1452-R

1

35-1452-R

23

Standoff, Mounting

2

50-0375

2

50-0375

* not depicted in drawing

All speci

fi

 cations, dimensional data, etc. are approximate and subject to change without notice.

Содержание Mighty Pure MP16A

Страница 1: ...PDLO LQIR XOWUDYLROHW FRP Extensive Product Information Available at ultraviolet com Document No 98 1376C October 2015 2015 Atlantic Ultraviolet Corporation Installation Operation Maintenance Read an...

Страница 2: ...INTENANCE NOTES 22 23 USER ASSISTANCE 24 WARRANTY 24 PATENT NOTICE 24 These instructions generally describe the installation operation and maintenance of the Mighty Pure line of water purifiers Models...

Страница 3: ...operate without proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warning...

Страница 4: ...r and flows into the annular space between the quartz sleeve and the chamber wall Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp The translucent sight port...

Страница 5: ...should be located in an area where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purif...

Страница 6: ...cted to the cold water line only 5 Installation requires that a 5 micron sediment filter or finer be installed in line prior to the water purifier The sediment filter will stop or trap large particula...

Страница 7: ...nstalled temporarily for shipping purposes Please follow these instructions if applicable 1 Pull off Easy Off end caps from static gland nut on each end of the water purifier chamber 2 Unscrew static...

Страница 8: ...8 Figure 3 Initial Installation of Quartz Sleeve...

Страница 9: ...lerts the user to any malfunction detected 6 Solenoid Valve Operated in conjunction with the Ultraviolet Monitor Safety Sensor or Time Delay Mechanism this valve prevents water flow through the water...

Страница 10: ...still in operation On purifiers not equipped with the Ultraviolet Monitor lamp operation can be verified by a visible glow through the translucent sight port This provides an indication of lamp operat...

Страница 11: ...to chamber until approximately 2 inches of the lamp is exposed on the opposite end Hold lamp and remove lamp socket 6 Lamp should now be disconnected on both ends Carefully remove lamp from chamber Be...

Страница 12: ...move Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that...

Страница 13: ...of quartz sleeve hold the purifier vertically and shake The quartz fragments will break and drop out of the purifier through the gland fitting Flush water through chamber being careful to remove all...

Страница 14: ...gent and rinse with clean water Stubborn stains usually can be removed with a dilute hydrochloric acid NOTE Follow all manufacturer s instructions and precautions when handling chemicals Once the quar...

Страница 15: ...or fittings Tighten suspect connection or fitting or shut down purifier drain and remove fitting or connection Clean threads reapply thread sealing tape and reinstall Poor purifier performance AND OR...

Страница 16: ...perature 35 F 100 F 35 F 100 F 35 F 100 F 35 F 100 F Quartz Sleeve 1 1 1 1 Drain Plug 1 4 NPT 1 4 NPT 1 4 NPT 1 4 NPT Lamp Out Indicator Translucent Sight Port Translucent Sight Port Translucent Sight...

Страница 17: ...elay Mechanism MP16A through MP49C Quantum Thermal Optimizer MP16A through MP49C Solenoid Valve MP16A 1 2 through MP22A 3 4 MP36C 1 MP49C 1 1 2 MP49C 1 1 2 Sure Flo Flow Control Valve MP16A 3 4 MP22A...

Страница 18: ...18 REPLACEMENT PARTS Mighty Pure MODELS MP16A MP22A Figure 8 Exploded View MP16A MP22A...

Страница 19: ...Quartz Sleeve 1 15 1111A 1 15 1112A 10 Sight Port Plug 1 30 1075 1 30 1075 11 Drain Plug 1 27 1216 1 27 1216 12 Speed Nut 6 32 2 50 1314 2 50 1314 13A Ballast 120v 60Hz 1 10 0137 1 10 0137 13B Ballas...

Страница 20: ...20 Mighty Pure MODELS MP36C MP49C Figure 9 Exploded View MP36C MP49C...

Страница 21: ...465G4 1 25 1465F5 12 Drain Plug 1 27 1216 1 27 1216 13 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034 14 Lock Washer 1 4 4 50 1321 4 50 1321 15 Flat Washer 1 4 4 50 1317 4 50 1317 16 Ballast Housing Cove...

Страница 22: ...22 MAINTENANCE NOTES...

Страница 23: ...23 MAINTENANCE NOTES...

Страница 24: ...een made to determine the patent status of applications illustrated or described in this publication Inclusion in this publication of any design or method of use which may be patented is not to be con...

Отзывы: