Atlanta Stretch S.p.A.
23
E08
Carriage ascend/descend
anomaly
-The sensor does not read the
petals because it is too far from the
phonic wheel.
-The carriage only moves in one
direction.
-The sensor does not send the
signal to the card.
-The roll holder carriage does not
move, even with manual controls.
-Adjust the position of the sensor compared to
the petals of the phonic wheel (distance < 2
mm). If the phonic wheel is broken or damaged,
it must be replaced.
-Check if the control signal reaches the drive,
then verify if the status LED is lit. Check if the
carriage limit switch is pressed or blocked.
-Check the correct operation of the sensor,
bringing it close to a metallic object. If the LED
lights up, replace the cable, if the sensor does
not work, it needs to be replaced.
-The drive or inverter does not receive consent
to start, check the wiring. The drive or inverter
is faulty, communicate the code shown on
the latter. For a DC motor, check the brushes.
The motor cable is not connected well, check
the wiring and tightness, even on the brake, if
present. The motor unit may be damaged or
defective; replace it. Check the battery.
E09
-
-
broken.
-
-
to the product.
-Change the roll.
-
-Check the proper operation of the dancer sensor
does not work, make sure the sensor is operating
-
(x)
seconds, the alarm is triggered. Attache
E10
Carriage limit switch
error
-Wiring or power outage error
-Check the limit switch wiring and power Check
the carriage motor brushes.
E11
Low limit switch error:
it did not close during
carriage ascent
-Carriage motor blockage
-Limit switch faulty or blocked.
-Check the carriage motor (motor brushes).
-Unblock the sensor or replace it if faulty. Check
the carriage motor brushes.
E12
High limit switch error:
it did not close during
carriage descent
-Carriage motor blockage
-Limit switch faulty or blocked.
-Check the carriage motor (motor brushes).
-Unblock the sensor or replace it if faulty.
E13
Low limit switch error: it
opened during carriage
ascent
-The carriage moves in the opposite
direction.
-Invert the rotation direction or the limit switches
are inverted.
E14
High limit switch error: it
opened during carriage
descent
-The carriage moves in the opposite
direction.
-Invert the rotation direction or the limit switches
are inverted.
Содержание EVA
Страница 2: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 2 ...
Страница 4: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST II ...
Страница 5: ...Atlanta Stretch S p A 1 1 1 1 1 1 1 Picture 1 ...
Страница 6: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 2 1 1 2 Picture 2 ...
Страница 7: ...Atlanta Stretch S p A 3 1 1 3 Picture 3 ...
Страница 12: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 8 1 2 1 2 1 Picture 5 ...