ATIM_ACW-DINRSM_UG_EN_V2.8
23
The ACW will return the information in the following format:
Description and Value
Octet 1
Response to command frames: 0x07
Octet 2
‘About’ command: 0x02
Octet 3
Type of ACW: DIN RS
–
0x06
Octet 4
ACW version (LSB)
Octet 5
ACW version (MSB)
Octet 6
Radio type:
1.
Local
–
0x01
2.
Local long distance
–
0x02
3.
Sigfox uplink only
–
0x03
4.
Sigfox uplink/downlink - 0x04
5.
LoRaWAN
–
0x05
Octet 7
Radio version (LSB)
Octet 8
Radio version (MSB)
Octet 9,n
Serial number (devEUI|sfx) (MSB first).
Note
: In LoRaWAN, the four high-order bytes are replaced by 0.
Restore default parameter settings
To restore the default parameter settings, you must send the following command:
Octet 1
Octet 2
0x01
0x03
The ACW will return a confirmation in the following format:
Description and value
Octet 1
Response to command frames: 0x07
Octet 2
‘Default settings’ command: 0x03
Octet 3
Indicates whether the reconfiguration was successful:
- returns 0x00 to indicate that the configuration was successful.
- returns a value other than 0x00 to indicate that the configuration failed.
Obtain complete configuration
To obtain the complete configuration (parameter settings) for the ACW, you must send it the following
command:
Octet 1
Octet 2
0x01
0x04