Never bypass protective devices or deactivate them.
16
Only hook up the machine by means of a fault-current
circuit breaker (30 mA).
The electrical connection or repairs to electrical parts
of the machine must be carried out by a certified
electrician or one of our customer service points.
Local regulations – especially regarding protective
measures – must be observed.
Repairs to other parts of the machine must be carried
out by the manufacturer or one of his customer
service points.
Use only original spare. Accidents can arise for the
user through the use of other spare parts. The
manufacturer is not liable for any damage or injury
resulting from such action.
A
A
s
s
s
s
e
e
m
m
b
b
l
l
y
y
Screw on both side parts (1+2).
For each side part you require:
2 cup square screws M 8 x 40
2 combi nuts M 8
Screw on the transverse joint (4).
For the connection you require:
4 cup square screws M 8 x 10
4 combi nuts M 8
Put the pre-assembled device unit on the side parts.
Fix first one side with each 2 round-head screws
M 5 x 16 and hexagon nut M 5.
Now fix the other side.
Then, fasten the four screw connections.
Put on the extraction hose (7).
Fasten the extraction hose by refastening the screw
on the hose clip (17) a few revolutions.
Put on the saw dust collecting bag (14).
Fasten the saw dust collecting bag by attaching the
quick release fastener (6).
Hang in the bag suspension (9).
Put on the filter bag (15).
Fasten the filter bag by attaching the quick release
fastener (6).
Hang in the filter bag.
S
S
t
t
a
a
r
r
t
t
-
-
u
u
p
p
Check that the machine is completely and correctly
assembled.
Put the saw dust extraction system on a place which
meets the following requirements:
−
firm and even ground
−
free of risks of stumbling
−
sufficient light and air conditions
Before using the machnine, make sure each time that
−
there are no faulty connections (tears, cuts, etc.)
Do not use any defective cables.
−
there are no damage at the machine (see safety
advices)
−
all screws are tight
L
Mains connection
Compare the voltage given on the machine model plate
e.g. 230 V with the mains voltage and connect the
machine to the relevant and properly earthed plug.
L
Use a shockproof plug, mains voltage 230 V with
residual current circuit breaker (FI switch 30 mA).
Only use
connection cables
with sufficient diameters.
L
Mains fuse: 10 A
L
Static charge
The complete extraction system is assembled of non-
electro-conductive components.
Do not replace synthetic parts by metallic parts.
Particularly, the extraction hose must not feature a
metallic coil.
When the extraction hose is fastened on electro-
conductive parts (e.g. metallic suction hoods or tubes)
these must be grounded for the discharge of possibly
appearing electrostatic energy.
On / Off Switch
Do not use any device where the switch can not be
switched on and off. Damaged switches must be
repaired or replaced immediately by the customer
service.
Switch on
Press the green button
( I ) on the switch.
Switch off
Press the red button
( 0 ) on the switch.