![ATI Technologies QC-50 Series Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/ati-technologies/qc-50-series/qc-50-series_manual_2998821032.webp)
Manual, Tool Changer, QC‑50
Document #9620‑20‑B‑50 Tool Changer‑04
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
B-32
7.
Specifications
Table 5.4—Troubleshooting
Specification
Values
Description
Recommended Max Payload
110 lbs. (50kg)
The mass attached to the Tool Changer.
Operating Temperature Range
-20–150°F
(-30–66°C)
Optimal operating temperature
Operating Pressure Range
60–100 psi
(4.1–6.9 bar)
Locking mechanism supply pressure operating
range. Supply to be clean, dry, and filtered to 40
micron or better.
Coupling Force @ 80 psi
1,300 lbs.
(590kg)
Axial holding force
Recommended Max Moment
X-Y (Mxy)
2,000 in-lbs
(226 Nm)
Maximum recommended working load for optimum
performance of the Tool Changer
Recommended Max Torque
about Z (Mz)
2,000 in-lbs
(226 Nm)
Maximum recommended working torque for
optimum performance of the Tool Changer
Positional Repeatability
0.0006”
(0.015 mm)
Repeatability tested at rated load at one million
cycles.
Weight (coupled, no access.)
5.09 lb (2.3 kg)
Master 3.37 lb (1.53 kg) / Tool 1.72 lb (0.78 kg)
Max. Recommended distance
between Master and Tool plate
0.1”
(2.5 mm)
No-Touch™ locking technology allows the Master
and Tool plates to lock with separation when
coupling.
Pass through Port, (Qty) Size
(Cv, Min)
(16) M5, and
(4) 1/8 BSPP
Maximum pressure of 100 psi (6.9 bar), Nitrile seals
Mounting/Customer Interface
Master plate
Tool plate
100 mm BC, (6) M8 Through Holes, (2) 8 mm
Dowels(SF)
100 mm BC, (6) M8 Through Holes, (2) 8 mm
Dowels(SF)