![ATI Technologies QC-50 Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/ati-technologies/qc-50-series/qc-50-series_manual_2998821013.webp)
Manual, Tool Changer, QC‑50
Document #9620‑20‑B‑50 Tool Changer‑04
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
B-13
2.11 Pneumatic Connections and Valve Requirements
The air supply used for coupling and uncoupling the Tool Changer should be clean, dry, and non‑lubricated.
A supply pressure in the range of 60 to 100 psi is acceptable for operation of the locking mechanism, with a
setting of 80 psi suggested. The air should be filtered 40 micron or better.
CAUTION:
Do not use the Tool Changer in a fail-safe condition. Do not transport the
Tool Changer in a fail-safe condition. Possible damage to the locking mechanism could
occur. Re-establish air pressure to Tool Changer before returning to normal operations.
2.11.1 Valve Requirements and Connections for the Locking Mechanism
NOTICE:
No valve is required when using a valve adapter module. The valve adapter
module has an integrated solenoid valve and only requires the customer to supply a
single air source to the valve adapter.
A customer supplied 2‑position 4‑way or 5‑way valve with either 4‑port or 5‑port configuration
must be used to actuate the locking mechanism in the Master plate. It is imperative that when
air is supplied to the Lock or Unlock Port on the Master plate, that the opposite port be vented
to atmosphere (i.e., when air is supplied to the Lock Port, the Unlock Port must be open to the
atmosphere.) Failure to vent trapped air or vacuum on the inactive port may inhibit operation of the
locking mechanism and prevent coupling or uncoupling.
CAUTION:
The locking mechanism will not function properly when connected
to a 3-way valve as this type of valve is incapable of venting trapped air or
vacuum from within the Tool Changer. This could result in damage to the
product, attached tooling, or injury to personnel. Connect the Lock and Unlock
supply air to a 2-position 4-way or 5-way valve with either 4-port or 5-port
configuration.
Figure 2.5— Lock and Unlock Pneumatic Connections
4 or 5 -way Valve
Supply Clean, Dry,
Non -lubricated Air
60 – 100 psi (4.1 – 6.9 Bar)
Exhaust
Open to Atmosphere
Lock Port
Unlock Port