Manual, Tool Changer, QC‑50
Document #9620‑20‑B‑50 Tool Changer‑04
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
B-25
5.2 Service Procedures
Component replacement procedures are provided in the following section.
5.2.1 Lock and Unlock Sensor Replacement
Parts required: Refer to
Tools required: 2.5 mm hex key, torque wrench
1.
Place the Tool in a secure location.
2.
Uncouple the Master and Tool plates.
3. Turn off and de‑energize all energized circuits; for example, electrical, air, water, etc. If
required, fully disconnect these circuits.
4. Remove any modules and spacer assemblies installed on Flat D.
5. Remove the (2) M3 socket head cap screws that secure the Lock and/or Unlock sensor assembly
to the Tool Changer body using a 2.5 mm hex key (refer to
assembly straight out from the Tool Changer body.
6. Discard the removed sensor.
CAUTION:
The Lock and Unlock sensor assemblies are precision aligned
and permanently assembled at the factory. Do not attempt to disassemble and
rebuild.
Figure 5.1— Lock and Unlock Sensor Assembly Replacement
Unlock Sensor Assembly
Lock Sensor Assembly
M3 Socket Head Cap Screw
Spacer Assembly
(If required)
Module on Flat D
M4 Socket Head Cap Screw
Master Plate
7.
Insert the new Lock and/or Unlock sensor into the Tool Changer body as shown in
Make sure the O‑ring is in place and seated properly on the back side of the sensor assembly.
8. Secure the sensor assembly with (2) M3 socket flat head screws using a 2.5 mm hex key.
Tighten to 12 in‑lbs (1.4 Nm).
9. Install any modules and spacer assemblies that were previously removed from Flat D.
10.
To confirm the operation of the Unlock sensor, unlock the Tool Changer and visually check that
the LED in the Unlock sensor body is on. To confirm the operation of the Lock sensor, lock the
Tool Changer and then visually check that the LED in the Lock sensor body is on.
11.
Safely resume normal operation.