21
22
6.2 Update on parameter setting page
Using this method for update doesn’t require any specific name for the firmware file.
1. Connect the charger to a computer with IP address set as 192.168.1.x(x can be any value
between 1 and 255 except 5) via a network cable. Open web browser and type in the
charger’s default IP address–http://192.168.1.5:8080, click enter then you’ll get into the
parameter setting page.
2. Scroll down to the below field.
During the update, the LED indicator will behave as below,
First flash red and goes out with a short beep sound, during this period the firmware file is
transmitted to the charger’s flash memory from the computer;
Then flash red again for some seconds and quickly change to green light flashing. During this
period, the charger is updating the firmware to its micro controller.
When the greenlight goes out, there will be a long beep sound. That means the firmware is
successfully updated.
The beep sound may not be audible with the front cover fixed on the charger.
If the update doesn’t start after click “Upload”, Turn off and back on the charge to try again.
4. You might see below content. If the charger is already successfully reboot after the
firmware update, close the browser and open it again to check the current firmware version.
3. Click the “Browse” button and select the firmware file. Click “Upload”, then update will
start automatically.