Modular Matrix Solution User Manual
148
Load Profile Commands
The Load Profile command allows you to apply one or multiple profiles to the
display zones.
The formula the Load Profile command is as follows:
Profile f + Num1 + A Num2 + C [Enter]
1. To load connection profile 04, type the following:
profile f04 load [Enter]
2. To load multiple profiles, type the following:
profile f1, 2, 4 load [Enter]
Note:
Each specified profile will be applied to the associated display zone.
If two or more profiles associated with the same display zone are
included in the command, the last one will be applied.
The following tables show the possible values for commands:
Command
Description
profile
Load profile command
Profile
Description
f
Profile command
Num1
Description
xx
Profile number
xx: 01-32 (default is 01)
Address
Description
a
Device address command
(RS-422 and RS-485 only)
Num2
Description
yy
Device address
yy: 01~16 (default is 01)
(RS-422 and RS-485 only)
*
All devices