38
© 2020 ATEÏS Europe B.V.
6.4.9.
To configure master audio levels:
Normal Preset, Night Preset, Attenuated Preset and Loud Preset are moved to Master level, according
to
normal,
night,
attenuated
and
loud
variable values, to control level on all outputs (loudspeaker lines 1
to 6, 0 dB output).
Evacuation signal are not affected by all group gains.
Inputs gain is controlling level only on analog audio inputs.
Messages Gain is controlling level only on messages.
IP Streams Gain is controlling level only on user decoders.
SIP Calls Gain is controlling level only on SIP calls.
Parameter
Access
Description
Master Level
Read / Write
Master absolute level (maximal level on PRIMA VA)
Music Gain
Read / Write
Master relative gain for all music sources (permanent routing or
music
command)
Normal Preset
Read / Write
Master level controlled by Normal variable (refer to Advanced config
> Variables section)
Night Preset
Read / Write
Master level controlled by Night variable (refer to Advanced config >
Variables section)
Attenuated Preset
Read / Write
Master level controlled by Attenuated variable (refer to Advanced
config > Variables section)
Loud Preset
Read / Write
Master level controlled by Loud variable (refer to Advanced config >
Variables section)