![ATAGO 3564 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/atago/3564/3564_instruction-manual_2995847020.webp)
19
8. External Output
WARNING
◇
When connecting or disconnecting the Recorder Output Cable or
RS-232C Cable to the main unit, be sure to turn off the power
(DC24V). If AD-32 (AD-33 or AD-34) is used, be sure to remove
the plug from the outlet before connecting these cables.
The instrument comes equipped with external outputs for a 4 to 20mA recorder and a
RS-232C.
(1) Recorder output
The Recorder Output provides a 4 to 20mA signal (open-circuit voltage is approx. 24V) of
the Brix(%) and temperature (-15.5 to 160.5 ˚C).
The Brix(%) range to be output through the 4 to 20mA signal is set as described in
Chapter 16 "Setting the Recorder Output." (See page 34.)
To utilize the 4 to 20mA signal, connect the Recorder Output Cable (optional) to the
Recorder Output terminal on the main unit.
Recorder output cable and code table
Fig. 8-1
Pin No.
Code color
Polarity
1
Red
Brix
+
2
Red/White
Brix
-
3
Black
Temperature
+
4
Black/White
Temperature
-