127
126
INSTALLATION GUIDE
Cut opening in worktop
Saw the opening in the worktop. This should be done very accurately
(see table). Also saw out any partitions that may be present.
The distance from the saw line to the rear wall and/or side wall is
indicated in the table.
Table
Space to be left free around the appliance
building in
Type of hob
HL60..G
HL60..M
HL70..M
Appliance width x depth
575 x 505 mm
x
614 x 514 mm
x
774 x 514 mm
x
Installation height from top of worktop
56
x
44
x
x
Cut out dimensions width x depth
560 x 490 mm
x
x
750 x 490 mm
x
Distance from saw line to rear wall
50 mm
50 mm
50 mm
Distance from saw line to side wall
50 mm
70 mm
55 mm
min. 600 mm (HL60..G en HL60..M)
min. 750 mm (HL70..M)
min. 650 mm
min. 450 mm
min. 40 mm
cooker hood
cabinet
side wall
Ceramic hob
min. 40 mm
3-phase connection (3 a.c. 230 V / 50 Hz):
The voltage between the phases and the neutral is 230 V a.c.
Install connecting bridges between the connection points 4-5. Uw groepen
moeten afgezekerd zijn met minimaal 16 A (3x). The connecting power
cable must have a minimum core cross section of 2,5 mm
2
.
You can use the bridges provided on the connecting block to make the
required interconnections as indicated in the preceding illustrations. How to
install the bridges is indicated in the junction box cover and in the
illustration below. The bridges should not be placed immediately on top of
the connecting wires, but between the screw-head and the clamp around the
connecting wire.
Secure the cable with the strain relief and close the cover.
electrical connection
INSTALLATION GUIDE