EN 25
Solutions for example 2:
• Move the pan within 10 seconds (away from the induction coil with a conflict). The originally
set power level (in this example level ‘8’) will be restored automatically.
• Accept the reduced power level. The conflict message goes out of view after 10 seconds.
• Reduce the difference in the power levels that are set for the pans.
Example 3:
a pan is put on an induction coil which is in operation already.
PWR
9
PWR
0
The pan with power level ‘9’ is heated with induction coil 2, 4, 5 and 7. If another pan (with power
level ‘0’) is put on induction coil 5 and 6, a conflict arises on induction coil 5. Induction coil 5 may
no longer supply any power now, because the power level requirement of the pan that was put
on the hob last, is ‘0’.
Solutions for example 3:
• Set a power level for the pan that was put on the hob last.
• Move the pan to another position on the hob.
All induction coils that are at least 5% covered with a pan with power level ‘0’ will not
supply any power.
CONFLICT MANAGEMENT