EN 11
SAFETY
Power management
A power management prevents the mains connection from overloading. The power management
is prioritizing, i. e. the pan with the last increased power level, will get the desired power level.
Another pan that is put on the same induction coil will be reduced in its power if the total power
request of the two pans exceeds 3.7 kW. In that case you hear an audio signal and the power
level of the pan will be reduced to the maximum possible power.
For safety reasons, the power level will not be increased to the power level that was set
before.
Cooling
‘Free Area’ Induction provides an efficient cooling concept using 1 fan per generator. The fans
operate with 2 different speeds to provide a low-noise operation. The fans also continue to
operate for a certain period of time if the hob switches to standby mode (after-cooling).
Cooking time limiter
The cooking time limiter is a safety feature of your hob. This limiter is activated when the cooking
time, as indicated in the table, is exceeded. Depending on the program or power level you have
chosen, the cooking time will be limited as follows:
Program / Power level
Automatic switch off after a cooking time
of:
Melting / Keep warm / Simmering
2 hours
1 / 1.5
10 hours
2 /2.5 / 3 / 3.5
5 hours
4 / 4.5
4 hours
5 / 5.5
3 hours
6 / 6.5 / 7 / 7.5 / 8 / 8.5
2 hours
9
1 hour
P
10 minutes (then it switches back to level 9)
Attention. If you have set a cooking timer with a cooking time that is longer as
indicated in the table, the time that is set for the cooking timer has priority.