GB
11
PPAARRAAMMEETTEERR 0033
Parameter 3 - Room sensor display
Setting range: OFF*, 1, 3*
Factory setting: 1
HHCC
Note:
The room sensor must not be activated:
– outside the area of unheated rooms, such as cel-
lars etc.
– in apartment blocks with different types of occu-
pation and different room temperatures.
Important:
If the actual room temperature drops more than
1 K below the actual room setvalue, an existing
summer shut-down will be disabled.
Applications:
All plants requiring monitoring and room temperature control.
* only when the outside sensor is connected.
This parameter activates the room sensor and enables all para-
meters which are related with the room temperature.
The following operating modes can be selected:
OFF*
The effect of the room sensor is completely disabled.
The parameters related with the room temperature
have no function. In the standard display, the boiler tem-
perature to the central heating system is shown.
1
The room sensor is activated, the unit displays the actual
room temperature.
3*
The effect of the room sensor is completely disabled, the
standard display shows the room temperature.
With the room sensor activated the heating circuit is still controlled
depending on weather conditions, whereby the magnitude of
the influence applied by the room is determined by the following
parameter 04
(ROOM SENSOR FUNCTION)
.
With the room sensor deactivated the room temperature no lon-
ger appears in the display.
next parameter
Page GB-30
8A520900_GB.qxp 12.11.2004 13:17 Seite 30
Содержание BrainQ RSC/2
Страница 2: ...NL GB F I Nederlands English...
Страница 36: ...NL Aantekeningen Pagina NL 36 8A520900_NL qxd 12 11 2004 14 46 Seite 36...
Страница 38: ......
Страница 72: ...GB Notes Page GB 36 8A520900_GB qxp 12 11 2004 13 17 Seite 36...
Страница 74: ...Art 0451003403 0445 20...
Страница 75: ...www atagheating com...