Asycube - Asyril SA
Programming Guide
©
Copyright Asyril S.A.
000.101.572
Version : A1
61/83
Address
(decimal)
Holding Register name
Read/
Write
Data Range
Comments
corresponds to -0.6 in the defined coordinate system.
19
HR_SEQUENCE_EXECUTION_SEQUENCEID
W
1 to 26
The sequence execution trigged with
HR_SEQUENCE_EXECUTION_TRIG
uses this sequence ID. More information in Section 5.4.10.1.
20 HR_SELECT_VIBRATION_SET
W
1 to 26
A value change of this Holding Register sets the new vibration set to use.
21 HR_SELECT_SEQUENCE
W
1 to 26
A value change of this Holding Register sets the new sequence to use.
22 HR_BACKLIGHT_STATE_CONTROL
W
0 or 1
A rising edge switches the backlight ON. A falling edge (value change from 1 to
0) switches the backlight OFF.
23 HR_EXECUTE_BACKLIGHT_FLASH_TRIG
W
0 or 1
A rising edge trigs a backlight flash. More information in Section 5.4.6.
24 HR_BACKLIGHT_INTENSITY_TRIG
W
0 or 1
A rising edge sets the backlight intensity value given in the Holding Register
HR_BACKLIGHT_INTENSITY.
25
HR_BACKLIGHT_INTENSITY
W
min
to 100
[%]
This backlight intensity can be set by trigging the HR_BACKLIGHT_INTENSITY
Holding Register. The
min
value corresponds to the minimum intensity settable
for the Asycube, which value can be read in the corresponding configuration
parameter (Section 4.1).
26 HR_PLATFORM_HALT
W
0 or 1
A rising edge halts the platform vibration.
27 HR_HOPPER_HALT
W
0 or 1
A rising edge halts the hopper vibration.
28 HR_SEQUENCE_HALT
W
0 or 1
A rising edge halts the sequence execution.
29 HR_READ_WRITE_PARAMETER_TRIG
W
0 or 1
A rising edge reads or writes an Asycube parameter (Chapter 4) with the
address
given
in
the
Holding
Register
HR_READ_WRITE_PARAMETER_ADDRESS. An even address trigs a read
where the resulting value can be read in the Holding Register
HR_READ_WRITE_PARAMETER_READ_VALUE (Address 64+13). An odd