5.4.6. Backlight
Code
Label
Command
Response
Remark
K1
Backlight On
{K1}
{K1}
After response received, the
backlight is considered ON, but
you must consider a delay to get
the maximal intensity.
K0
Backlight Off
{K0}
{K0}
K?
Backlight State
{K?}
{K?:0}
{K?:1}
0: Backlight is off
1: Backlight is on
KF
Backlight is flashing
{KF}
{KF}
Duration = Parameter 100
Table 5-11: backlight commands
5.4.7. System States
The Asycube has two different working states:
-
Service mode is the normal mode, to work with the Asycube.
-
Standby mode is a special mode. In this mode the power of vibrations, outputs, backlight,
etc. are off. Operator can send commands without any physical action on the Asycube.
This mode can be useful for tests and debug.
Code
Label
Command
Response
Remark
HC
Halt Platform Vibrations
{HC}
{HC}
Stop the platform actuators
HB
Halt Hopper vibration /
Outputs Activation
{HB}
{HB}
Stop the hopper actuator or
the outputs
HS
Halt
{HS}
{HS}
Stop the sequence
H1
System in service
{H1}
{H1}
Set system in service
H0
System in standby
{H0}
{H0}
Set system in standby
H?
System State
{H?}
{H?:0}
{H?:1}
0: System in standby
1: System in service
Table 5-12: system states commands