III. Data Review and Playback  

 

Data capture records can be reviewed on the display as well as on the chart paper.  
During review, the timebase can be expanded or compr essed to give appropriate detail 
of the signal. 

 

 

ACTION

 

HOW TO

 

 

 

Enter Data Capture Playback

 

[MODE] [DATA PLAYBACK]

 

 

 

Setup Playback 

[SETUP PLAYBACK]

 

 

 

Enable printing of record info 

Toggle 

[REPORT]

 key to 

on

.  This will print out the header information. 

 

 

Show where the trigger point is 

Toggle 

[TrigMark]

 key to 

on

.  This will highlight the trigger point with a  

 line across the chart. 

 

 

Play back all of the capture 

[MODIFY WINDOW ] 

Press the 

[100%]

 key.   

[EXIT] 

 

 

 

Compress the playback 

[SET MAGNIF]

 

 

Turn encoder wheel so that expansion is 

X 1/8

 

 

Select chart format for playback 

[SET FORMAT]  

Be sure output format is 

Chart 1

 

 

Play back data to paper and display 

[SET DEVICE]   

Turn encoder wheel so output device reads “

display & chart

”.  

[EXIT]  

 

 

 

Play out data capture 

[RUN PLAYBACK]

 

 

 

Zoom in on the trigger point  

[SETUP PLAYBACK] [MODIFY WINDOW ]  

 

With

 

[UNITS] 

set to percentage, press the 

[START] 

key and turn encoder wheel to 

8%

.  

Press the 

[END] 

key and turn encoder wheel to 

12%

.   

[EXIT] 

 

 

 

Expand the playback 

[SET MAGNIF]

 

 

Turn encoder wheel so that expansion is 

X 2

.     

[EXIT] 
[EXIT]   

 

 

Play out data capture 

[RUN PLAYBACK]  

 

 

 

… this completes the exercise.

 

 

 
 
 

 

 
 
 

Throughout the setup of the Dash 10, you can consult the manual for additional help . This Quick Start  Guide provides the basic 
information for operating the Dash 10. Under many of the menus, you will find  additional choices for more advanced capabilities of 
the  Dash 10, and the Operations Manual provides information on utilizing these features.  
Should you require additional assistance, you can contact our Technical Support Department toll -free at 800 -343-4039 or 
by e-mail: 

[email protected]

 

Содержание Dash 10

Страница 1: ...Established 1981 Advanced Test Equipment Rentals www atecorp com 800 404 ATEC 2832...

Страница 2: ...TS AND GRIDS 4 SETTING UP ZERO AND GAIN 5 ENTERING TEXT ANNOTATION 6 SETTING UP DATA CAPTURE PLAYBACK 7 SAMPLE EXERCISE Astro Med Inc Astro Med Industrial Park 600 East Greenwich Ave West Warwick RI 0...

Страница 3: ...e date speed and the state of the recorder realtime or halted DEDICATED MENU KEYS To the left of the display a column of five black buttons are located To the right of the display a column of five bla...

Страница 4: ...in any integer from 1 to 200 in two ranges mm sec mm min Let s try Press the SPD key The SPD menu will appear SPD MENU mm s CHART SPEED mm m 25 mm sec ACCEPT CHART SPEED INSTA SPEED MOTOR SOURCE DLOG...

Страница 5: ...position zero suppression channel mode and filter status settings Trigger Status provides information on low level high level and window trigger settings Capture Status provides information on data p...

Страница 6: ...HANGE GRID menu will appear Press the soft key above TYPE to change between standard and t based grids standard grids are printed in standard 5mm increments and are not synchronized with the recorders...

Страница 7: ...include zero and gain settings speed settings edit settings and trigger settings Setups are saved to floppy disk See the Operations Manual for information on how to save modes Let s demonstrate how c...

Страница 8: ...as an input range of 50mv to 500V peak To change the range of a specific channel Press the soft key below RANGE The range parameter will be blinking Either turn the encoder wheel or use the alphanumer...

Страница 9: ...r Press the front panel EDIT key The EDIT menu will appear The word Syslog under BUFFER should be blinking This indicates the attribute that you are working on in this case it is the SYSLOG BUFFER Tur...

Страница 10: ...t you want to use is setup to on If it is not set to on the data capture will not occur Press the soft key above BRD until the data capture board you want to setup is selected Select BRD 1 You will on...

Страница 11: ...o on by pressing the soft key above MANUAL until on is displayed Turn the other triggers Host Wave External and Periodic to off by pressing the soft key above HOST WAVE EXTERNAL AND PERIODIC until off...

Страница 12: ...ur selection As you rotate the encoder wheel you will see the value of the parameter changes in the display In this exercise the encoder wheel values that you will select are listed in bold font ACTIO...

Страница 13: ...ring is OFF Autotrig Autotrig is self triggering That is the Dash 10 triggers itself as soon it is armed for a data capture If auto triggering is ON toggle to OFF Set capture for one record CAPTURE CO...

Страница 14: ...ata to paper and display SET DEVICE Turn encoder wheel so output device reads display chart EXIT Play out data capture RUN PLAYBACK Zoom in on the trigger point SETUP PLAYBACK MODIFY WINDOW With UNITS...

Отзывы: