www.Astria.US.com
126688-01A
11
INSTALLATION
Continued
1
1
/
2
" Max.
3/8" Max.
4"
8" Min. from adjacent
wall to fireplace opening
SAFE
ZONE
Combustible material must
not overlap more than 3/8"
onto black metal front face.
Nailing Flange
Drywall
Figure 9 - Framing for Built-In Firebox
Installation, Top View
Min. from firebox
edge to combustible
material
Edge
of side
firebox
opening
IMPORTANT:
When finishing your firebox,
combustible materials such as wall board,
gypsum board, sheet rock, drywall, plywood,
etc. may be butted up next to the sides and
top of the firebox. Combustible materials
should never overlap the firebox front facing
more than 3/8".
WARNING: Do not allow any
combustible materials to over-
lap the firebox front facing (see
Figure 9).
IMPORTANT:
Noncombustible materials such
as brick, tile, etc. may overlap the front facing,
but should never cover any necessary open-
ings like louvered slots.
WARNING: Never modify or
cover the louvered slots on the
front of the firebox.
WARNING: Use only non-
combustible mortar or adhe-
sives when overlapping the front
facing with noncombustible
facing material.
WARNING: Do not fill the
spaces around the firebox with
insulation or other materials.
WARNING: Framing may be
placed or rest against fireplace
spacer, however; framing must
never be notched.
WARNING: Do not alter, cut
or modify fireplace spacers.
Figure 10 - Attaching Firebox to Wall Studs
Nailing
Flanges
Nails or
Wood
Screws
INSTALLING GAS LINE
WARNING: A qualified ser-
vice person must connect ap-
pliance to gas supply. Follow all
local codes.
IMPORTANT:
See
Connecting to Gas Supply
in your log set owner’s manual for details on
gas hookup.
Figure 11, page 12, shows the typical in-
stallation for the gas line. When you have
determined how the gas line will run, locate
one of the recessed knockouts in the fire-
brick floor (see Figure 12, page 12,). Firmly
tap the center of the knockout with a chisel
until it is released. Carefully chisel the rough
edges of the hole you have made to smooth
edges. This hole will line up with the hole in
the metal floor.
Nails or Wood
Screws