Prepare incoming black iron gas line with
Teflon tape or pipe joint compound (check with
local codes as to the use of Teflon tape). Com-
pounds used on threaded joints of gas piping
shall be resistant to the action of propane/LP
and should be applied lightly to ensure excess
sealant does not enter the gas line.
Complete your gas installation by connecting
the incoming gas line to the appliance regula-
tor. Secure all joints tightly with wrench but do
not overtighten. If a flexible gas line is used,
take care not to kink the connector.
WARNING: All gas piping
and connections must be tested
for leaks after the installation is
completed. After ensuring that
the manual shutoff gas valve is
open, apply a soap and water
solution to all connections and
joints. If bubbles appear, leaks
can be detected and corrected.
DO NOT USE OPEN FLAME FOR
LEAK TESTING AND DO NOT
OPERATE ANY APPLIANCE IF
A LEAK IS DETECTED.
INSTALLATION
Continued
GAS SUPPLY TESTING
Note: This section is intended as a guide for
qualified technicians installing gas to this
vent-free firebox.
CAUTION: Do not connect
vent-free appliance before pres-
sure testing gas piping. Damage
to gas valve may result and an
unsafe condition may be caused.
The appliance and its’ individual shutoff valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at test pressures in excess of 1/2
psig (3.5 kPa).
The appliance must be isolated from the gas
supply piping system by closing manual shut-
off valve during any pressure testing of the gas
supply piping system at test pressures equal
to or less than 1/2 psig (3.5 kPa).
Figure 15 - Locating Electrical
Connection and Gas Connection on
Either Side of Fireplace
HARD-WIRING FIREBOX
This model can be hard-wired to the duplex
outlet located inside the firebox bottom if
desired. This allows the blower accessory to
be plugged into the duplex outlet.
NOTICE: A qualified electrician
must connect electrical wiring to
duplex outlet for built-in instal-
lation. Follow all local codes. In
absence of local codes follow
The National Electric Code ANS/
NFPA 70.
ELECTRICAL INSTALLATION
A model GA3500A blower system assembly
is available for use with the vent-free firebox
as an optional accessory. This blower is
designed to be installed on either side of
the firebox, when provisions for a 120 VAC
supply connection are made at either end
of the cabinet. Use of a blower system other
than those manufactured by INNOVATIVE
HEARTH PRODUCTS voids the warranty.
Electrical connections are made within the
receptacle with wires that are routed through
the bushing provided (see Figure 15). The re-
ceptacle may be relocated to either side, when
necessary. However, the cover plate must be
replaced over the unused access point. Be
certain to properly ground the vent-free firebox
using the green grounding wire.
Note: A 120V supply connection to the leads
Cover
Plates
Electrical
Connection
Access Hole
Gas Connection
Access Hole