![Astria Fireplaces Gemini-C Series Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/astria-fireplaces/gemini-c-series/gemini-c-series_installation-and-operation-instructions-manual_2990892053.webp)
Operation
900912-00C, 04/2019
Innovative Hearth Products
Gemini™ -C Series Direct-Vent Gas Fireplaces
53
Installing the Firebox Liners
1.
Remove the firebox liner panels from the packing materials.
2.
Carefully position the rear panel, upper edge first, in the firebox against the rear wall.
3.
While holding the rear panel, carefully position the left side panel in the firebox.
4.
Carefully position the right side panel in the firebox.
NOTE: Do not force the panels. Excessive force may cause breakage. If the panels are correctly positioned, they will
fit snugly in place.
5. (
Fiber Panels Only) Place the front “ember strip pieces” last.
NOTE: If adequate space for the ember strips was not provided the grate can be adjusted by loosing the two
attachment screws and pulling the grate up then re-tightening the screws.
Gas Controls
The standard controls for fireplace operation are located in the control compartment, below the glass door
(
Figure 38A
). Optional control switches are also available.
Familiarize yourself with the gas control valve and the lighting procedure (
Pages 66-67
).
Millivolt Fireplaces
Detailed lighting instructions are found on
Pages 66-67
. Also, millivolt fireplace lighting instructions are found on
the pull-out lighting instructions attached to the gas control valve.
When the pilot is lit, the main burner can be turned ON/OFF using a wall switch, remote control, optional on-unit
rocker switch (FRS), or wall thermostat.
If the millivolt fireplace is equipped with an optional remote switch (wall switch, remote control, rocker switch, or
wall thermostat) and the pilot is lit, the fireplace main burner can be turned ON/OFF using the optional switch.
NOTE: Do NOT wire more than one valve to the burner control switch. This will help prevent excessive resistance in
the burner circuit, that can cause burner operation problems.
f i r e - p a r t s . c o m