![Astria Fireplaces Gemini-C Series Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/astria-fireplaces/gemini-c-series/gemini-c-series_installation-and-operation-instructions-manual_2990892022.webp)
Installation
900912-00C, 04/2019
Innovative Hearth Products
Gemini™ -C Series Direct-Vent Gas Fireplaces
22
VENT SYSTEM PREPARATION
8.
Select a Horizontal or Vertical Vent System
1. With the fireplace secured in the framing, determine the vent route and identify the exterior termination location.
The following sections describe vertical (roof) and horizontal (exterior wall) vent applications. Use only approved
vent components. See
Pages 28 - 29
(vertical) and
Pages 33 - 35
(horizontal).
NOTE: This fireplace must be vented directly to the outside.
WARNING
The vent system may not service multiple appliances, and must never be connected to a
flue serving a separate solid fuel burning appliance.
NOTE: The vent pipe is tested to be run inside an enclosed wall. There is no requirement for inspection openings in
the enclosing wall at any of the joints in the vent pipe.
Figure 11B
Figure 11C
Figure 11D
2. Place Top trim piece and hood that is included with façade on unit and
install using three screws (see
Figure 11B
).
3. Remove four shoulder screws from fireplace.
4. Install one side of trim kit on fireplace using 2 previously removed
shoulder screws.
5. Install other side of trim kit on fireplace using 2 previously removed
shoulder screws.
6. Install bottom trim if needed using 3 provided self-tapping screws
(see
Figure 11C
).
7. Once trim kit is installed the facade can be installed on the fireplace.
NOTE
: The façade will not sit completely flush against trim kit (see
Figure 11D
).
Top Trim
Hood that is pro-
vided with facade
Shoulder screw
Side trim piece
Side Trim Piece
Bottom Trim Piece
Shoulder Screw
Install The Rock/Stone Stop Kit (continued)
f i r e - p a r t s . c o m